CAUTION! Risk of Glass Damage and Cuts! DO NOT
drill or install any type of screw or fastener into the lower
cover panel. Sharp screw or fastener tips may penetrate
and break the glass or cause cuts.
The RED40 comes standard with a mesh front. The fi nal
fi replace installation can be accomplished by either the
"overlap" or "inside-fi t" method. Reference Section 13.D
regarding installation details associated with the Inside
and Overlap Fit methods.
If the fi nal fi replace installation uses the Overlap Method,
wall sheathing material 3/8 in. (10 mm) thick is specifi ed
and can be installed tight to the side fi nishing fl anges
and factory-supplied non-combustible board. If the fi nal
fi replace installation uses the Inside-Fit Method, additional
clearance must be maintained between combustible
3/8 in. (10 mm) thick wall sheathing material and the
side fi nishing fl anges.
installation details associated with the Inside and Overlap
Fit methods and specifi ed additional non-combustible
materials required.
When fi nishing the wall around the fi replace, it is critical
that wall sheathing be fastened properly. Wall sheathing
fasteners, such as screws or nails, are not permitted in
some locations. See Figure 13.2. It is acceptable to
pre-drill holes and use self-tapped screws in the factory-
installed non-combustible board which may be used
to lathe (a backer for tile, marble, etc.) Screws being
installed through the factory-installed non-combustible
board should be self-tapping type with a maximum length
of 2 in. (51 mm) See Figure 13.1. Do not drill or install
screws which may penetrate the lower cover panel as this
will restrict required access to the glass and lower control
chamber. See Figure 13.1.
The appliance is designed to mate with 3/8 in. (10 mm)
wall sheathing materials such as drywall, plywood, wood
composites, or non-combustible materials.
of material used depends whether the installation is an
Inside or Overlap Fit method. Reference Section 13.D
regarding installation details associated with the Inside an
Overlap Fit methods.
Verify that the lower cover panel is installed correctly, and
that there are no screws used to attach drywall to the panel.
58
See Section 13.D regarding
The type
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
SIDE FINISH NON-COMBUSTIBLE
BOARD (2)
47 in. (1194 mm) WIDTH
FACTORY INSTALLED NON-COMBUSTIBLE BOARD
Figure 13.1 Finishing Details
Note: It is acceptable to use a high temperature silicone
sealant to adhere drywall to lower cover panel.
33-1/2 in. (851 mm) HEIGHT
FACTORY INSTALLED
NON-COMBUSTIBLE BOARD