Note: This appliance does include a manual gas shutoff
valve that is located in the valve compartment. This manual
gas shutoff valve is accessible for service by removing
the outer access panel tray or the base pan and burner
assembly and inner access windows. Depending upon
local code, an additional manual gas shutoff, in a readily
accessible area may be required and located upstream from
the appliance.
The lower access cover panel is removable if fi nishing
material is not installed. See Figure 11.4.
If the fi nishing materials have been installed around the
appliance opening, proceed as follows:
1. If already installed, carefully remove the front media
and tray and/or refractory from the appliance and set
aside.
2. Unplug the transformer from the junction cord. This
will turn the power off to the appliance.
3. Turn the gas shutoff handle to the "OFF" position to
shut off the gas supply.
4. Remove the glass assembly from the appliance by
unlatching the two bottom spring latches and then
pulling the bottom of the glass assembly toward you
until it clears the glass latch tabs. Hold the top of
the glass frame and gently lower the glass assembly
down until it rests on the side glass supports. Tilt
the top of the glass out toward you and remove. See
Section 14.G.
5. Remove any interior media and refractory from the
unit if already installed.
6. There are three access windows located on the interior
of the fi rebox bottom. See Figure 11.4. Remove screws
and plate to access the manual shutoff valve included
with this fi replace.
To access unit through the lower bottom windows:
1. Remove the glass media and/or refractory from the
interior fi rebox.
2. Remove the base pan. It is attached with 10 screws to
the interior fi rebox bottom and with 12 screws to the
burner assembly. If your appliance is a model that has
the glass media, you must also remove the pilot shield
cover at this time. See Figure 11.2 and Figure 11.4.
3. Remove the two screws securing the burner to the
fi rebox sides and disengage burner from over orifi ce.
Remove burner. See Figure 11.2.
4. Remove access panel covers or glass windows, along
with gaskets. Gaskets may be fragile. Handle with
care. See Figure 11.4.
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
PILOT SHIELD
(INSTALLED ON MODELS WITH LIGHT MEDIA OPTION)
INNER BASE PAN TRAY
SCREWS TO DISENGAGE
BURNER ON EACH END
Figure 11.2. Base Pan with Burner and Pilot Cover
GAS SHUT OFF VALVE
GAS SHUT OFF VALVE
Figure 11.3 Gas Fitting Access
ACCESS PANEL
(For use prior to finishing)
OUTER ACCESS PANEL TRAY
(For use after finishing)
Figure 11.4 Gas and Electrical Access
SCREWS TO DISENGAGE
BURNER ON EACH END
BURNER ASSEMBLY
INNER ACCESS WINDOWS
(FOR USE AFTER FINISHING)