Top Vent - Vertical Termination
No Elbows
V = 3 ft Min. (1m), 50 ft. Max. (15.2 m)
Note: If installing a vertical vent/termination off the top of the
appliance, the optional exhaust restrictor may be needed.
Note: Use DVP Series
components only.
V
Figure 7.7 Vertical Vent Maximum
Exhaust restrictors are recommended for these vertically
terminated products which have excessive draft. Exhaust
restrictors will compensate for high draft, and restore vi-
sual fl ame height. If the vent confi guration has a total
vertical of 14-50 ft (4.5 m -15.24 m), an exhaust restrictor
may be needed. The exhaust restrictor can be located in
the appliance manual bag.
28
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
Exhaust restrictor Instructions
1. Locate the two pilot holes in the inside fi rebox cham-
ber as shown in Figure 7.8.
2. Center the exhaust restrictor such that the thru holes
in the vent restrictor align with the pilot holes in the
inner fi rebox chamber.
3. Use two 1/2 in. (13 mm) self-piercing screws to se-
cure vent restrictor to fi rebox heat shield. See Figure
7.8.
EXHAUST RESTRICTOR
Figure 7.8 Exhaust Restrictor
4. In some applications, such as those where the fi re-
place is elevated off the fl oor, the vent restrictor may
be painted, but painting is not required.
5. Recommended restrictor usage:
14 to 30 ft. (4.5 m to 9.1 m) = 4 in. (102 mm) restrictor
30 ft. (9.1 m) and up = 2.4 in. (60 mm) restrictor
NOTICE: Before painting, contact your dealer for
information on the appropriate high temperature paint.
For all Horizontal Termination confi gurations, use
Ø102 mm restrictor plate.
For all Vertical Termination confi gurations greater than
4.5 m, use Ø60 mm restrictor plate.