Prints light on the right side of the label
•
The media width adjustment thumbwheel is set for a
narrower media width than the actual media being used,
(see Section 1.9).
•
The printhead is adjusted for thick media or cardstock.
•
The printhead is not properly aligned, call for service.
•
The printhead is not locked down.
Printer fails to turn on
•
A fuse may be blown, call for service.
•
Faulty AC cord.
•
A bad power switch may exist on the printer, call for
service.
•
A faulty AC wall outlet.
Label advances 1-2 inches before a fault indication
•
The ribbon is installed incorrectly. Make sure that the dull
side (side with ink) is facing the paper.
•
A bad ribbon/paper combination is resulting in an
insufficient amount of friction between paper and ribbon.
Ensure that the correct type of ribbon is being used.
Label advances 12 inches before a fault indication
•
The media sensor or media sensor circuitry may be
defective, call for service.
34
Troubleshooting
Ovation!™