1.10 Power-up Configuration and Self-Test

With the printer off, load the die-cut media (the media must be at
least 4 inches wide), and ribbon (if printing in thermal-transfer).
Press and hold the feed button and turn the printer on, (the power
LED should be 'on'), continue holding the feed button until the
media begins to move then release it. The printer will automatically
detect if a ribbon has been installed and will then print two test
labels.
Note:
After performing a power-up and self-test, the printer will
be in the 'character dump mode'. Turn the printer 'off' for
approximately 25 seconds, then back 'on' to restore normal
operation. The printer must remain 'off' for 25 seconds in
order for the main board to properly reboot.
The first label printed will be the configuration label, which lists the
printer's configuration and status. Note that this configuration label
shown below was printed from a printer that had the time/date
option installed.
FRI SEPTEMBER 026,
ROM CHECKSUMS
U09
U10
SYSTEM RAM CHECKS____ GOOD
KBYTES
CONFIGURATION
9600,8,N
DIRECT
INPUT VALUES
PAPER: 228
POT
: 212
COUNTER INFORMATION
ABSOLUTE VALUES
1994
LENGTH____
INCHES
TIME______
HOURS
MEMORY CONFIGURATION
Ovation!™
Getting Started
1997 19:29 244
EDGE: 179 REFL:
TOFA: 133 RIBN:
9-18-1994
773 INCHES
10 HOURS
SYSTEM RAM SIZE__ 512
0 TEMP:
89
0
RESETTABLE VALUES 9-18-
LENGTH____
TIME______
576
4
11