AGFA Ovation! Operator's Manual page 28

Thermal
Table of Contents

Advertisement

The system-level commands are used to create formats, load and
store graphic information, and control the printer. Table 2-3
provides a brief description and format of each system-level
command character.
Char
A
Set time and date
a
Enable feedback characters
B
Get Printer time and date information
c
Set continuous paper length
d
Set Printer to double buffer mode
E
Set quantity for stored label
e
Select edge sensor
F
Form feed
f
Set form stop position (Backfeed)
G
Print last label format
I
Input graphics data block
"See Programmer's Manual for format"
i
Download scalable font
J
Set pause for each label
K
Extended System Commands
k
Test RS-232 Port with a Y if ok
L
Enter Label Formatting Mode
M
Set maximum label length
Table 2-3 System-Level Commands (continued)
20
Printing Lables
Description
Format
FORMAT: AwmmddyyyyhhMMjjj
16 digits total.
w
= 1 digit week, 1 is Monday
mm
= 2 digits for month
dd
= 2 digits for day
yyyy
= 4 digits for year
hh
= 2 digits for hour (24 hr ft)
MM
= 2 digits for minutes
jjj
= 3 digits for Julian I.D. value
Returns 30 after each label and 31 after
each batch of labels
Print time and date to port
cnnnn = length of paper to feed per label
Use to print a label while a second is
formatting in memory
Ennnn = Set Quantity for stored label
for "see through" media sensing.
Feeds one label at a time
Set distance to peel (tear off) position
fnnn = 3 digits from sensor
A bank designation, an optional word
length modifier, a format designation,
and up to a 16-character string to identify
the stored image data
Kn
n =
Q - For query
D - Database Configuration
S, W, or M - Set configuration
R - Reset
fxxxx- 4 digit number, Distance between
TOF sensor and stop position
r - Resettable counters reset
Sends character "Y" to RS-232 port
Mnnnn = 4 digits (default) Maximum 12
inches