2.3

Configuration Command String

The configuration command string sets the operating parameters of
the printer. The command strings are described below.
<STX>KDwxy
where w:
Bit #
Function
0-2
Baud Rate
3
Word Length
4&5
Unused
6
Always 1
7
Always 0
where x:
Bit #
Function
0
Print Method
1
Present Sensor
2
Alternate Char. Set
3
Cutter
4&5
Unused
6
Always 1
7
Always 0
where y:
Bit #
Function
0&1
Paper Type
2
Linerless
3-5
Unused
6
Always 1
7
Always 0
* = factory defaults
Example: <STX>KD @A@
@
Sets the printer to: 9600 baud; 8 bit word length/no parity.
A
Sets the printer to: thermal transfer; no present sensor;
standard character set; no cutter.
@
Sets the printer to: gap (edge) media; no linerless.
26
Printing Lables
<CR>
Value
0=9600*, 1=600, 2=2400, 3=19200, 4=4800, 5=N/A,
6=1200, 7=9600 Test Mode
0=8 bits*, 1=7 bits
Set to 0
Set to 1
Set to 0
Value
0=direct thermal*, 1=thermal transfer
0=not equipped, 1=equipped
0=standard*, 1=main frame
0=disabled*, 1=enabled
Set to 0
Set to 1
Set to 0
Value
0=gap*(edge), 1=reflective, 2=continuous (3")
0=not equipped*, 1=equipped
Set to 0
Set to 1
Set to 0
<CR>