4.2.11 Operator panel PCB/ Top Cover Handle
(1) Detach the control panel assembly. (See Subsection 4.2.10.)
(2) Release two claws A, as illustrated in Figure (2), and remove frame OP1, lever lock 2 and
spring compression 3.
(3) Release two claws B by forcing in the flat-tipped screwdriver, and remove the cover assembly
OP4 and spring torsion 5.
(4) Release two claws C of the cover assembly OP 4, as shown in Figure (3), and remove
Operator panel PCB 6 and cable 7.
Claws A
Figure (2)
43827101TH Rev.2
2
Claws A
3
5
Figure (1)
Figure 4-2-11 Operator panel PCB/ Top Cover Handle
1
7
Claws B
6
Oki Data CONFIDENTIAL
4
Claws C
Figure (3)
82 /