Troubleshooting - Vulcan-Hart VK Series Service Manual

W/wo kleenscreen plus
Table of Contents

Advertisement

VK and TR GAS FRYERS W/Wo KleenScreen PLUS - TROUBLESHOOTING
SYMPTOMS
Ignition lockout, continuous loud beep
Initial beep then shut off
No spark no blower
"Puffing" during initial start up
Burner lights but will not maintain flame
F45474 (0413)

TROUBLESHOOTING

TROUBLESHOOTING
ALL MODELS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Vent hose closed off or restricted.
1.
2.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
1.
2.
3.
Page 54 of 55
POSSIBLE CAUSES
Harness connection to gas valve.
Gas valve or gas pressure.
Air filter.
All harness connections.
Electrode.
Drain valve switch open or switch malfunction.
Interconnecting wiring malfunction.
Ignition module malfunction.
High limit or thermostat open.
Grounding status.
Check electrode.
Harness connections (check for flashing light in A
control).
Probe lead wires.
Open probe.
Controller.
Open fuse on ignition/blower control board
Air Filter dirty.
Incorrect gas pressure.
Vent hose closed off or restricted.
Cracked electrode.
Electrode gap exceeding 3/16".
Igniter/flame sense misaligned.
Insufficient gas pressure.
Incorrect polarity from transformer to ignition
module.

Hide quick links: