4-4. Processing after Completing Adjustments
Order Page Address Data
1
2
30
00
2
3
33
00
3
0
01
00
Procedure
Set the data.
Set the data.
Set the data.
5. PLL fo & LPF fo Final Adjustment (VC-260 board)
RadarW
RadarW
RadarW
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
3
01
3
3
02
4
3
03
5
0
01
Note1: If it isn't satisfied, there are errors.
Note2: If the data of page: 3, address: 03 is other than "00", there are
errors. For the error contents, see the following table. (For the bit
values, refer to "5-4. SERVICE MODE", "4-3. 3. Bit value
discrimination".)
Bit value of page: 3,
address: 03 data
bit 2 = 1 or bit 3 = 1
bit 4 = 1 or bit 5 = 1
bit 6 = 1
5-44
VTR stop
Arbitrary
Display data of page: 3, address: 02, 03
Adjustment remote commander
C
1F, 20, 22, 29
Data of page: 3, address: 02 is "00".
Data of page: 3, address: 03 is "00".
Procedure
01
Set the data.
30
Set the data, and press PAUSE
button.
Check that the data changes to
"00" with in 5 sec. (Note1)
Check that the data is "00".
(Note2)
00
Set the data.
Error contents
PLL fo fine adjustment is defective
PLL fo adjustment is defective
LPF fo is defective