2-4-4. Processing after Completing Adjustments

1. Processing after Completing Adjustments
After completing the adjustments and operation checks, return a camera to factory default setting state as
following procedures.
(1) Transmission at 8101062213FF (Receiving of debug command enabled)
Commands of 9041FF and 9051FF are returned to Response Window.
(2) Transmission at 8101061F02FF (Receiving of adjustment command disabled)
Commands of 9041FF and 9051FF are returned to Response Window.
n
In these commands, completing initialized message is not transmitted to a camera.
(3) Turn on the power again
Turn off the DC power once, then turn on the power again. Confirm a command
NetworkChangeMessage (9038FF) is returned to Response Window. Also, confirm muting effect of
the video output (Blue back screen is not displayed) until initialize operation of the pan and tilt are
completed.
(4) For each switch setting, make sure return to set the original user setting.

2-5. Confirmation of Product Date

2-5-1. Preparation

(1) Install VISCA communication software to a personal computer.
(2) Connect a personal computer to a camera with VISCA cable.
(3) Turn on the power of a camera.
(4) Run VISCA communication software.
n
When VISCA communication software does not boot and "No Camera Connected!" message is displayed
in this state, VISCA communication is not established with a camera. Therefore, confirm the cable
connection and camera condition.
2-5-2. Confirmation of Product Date
Perform the confirmation by transmitting of VISCA command as following procedures. Input the each
command to Direct Command window of communication software, press the Enter key to transmitting
the each command.
(1) Transmission at 8101062213FF (Receiving of debug command enabled)
Commands of 9041FF and 9051FF are returned to Response Window.
(2) Transmission at 8101061a0300FF (Data reading of the year)
Commands of 9041FF and 905102000p0qFF are returned to Response Window.
The product year becomes 20pq.
(3) Transmission at 8101061a0301FF (Data reading of the month and day)
Commands of 9041FF and 90510p0q0r0sFF are returned to Response Window.
The product month and day becomes rs (day) and pq (month).
n
As product date is equivalent to the produced date of the unit in the factory, so it is differ to purchase date
of the customer.