Apc & Aeq Adjustment (Vc-264 Board); Processing After Completing Adjustments; Pll Fo & Lpf Fo Fine Adjustment (Vc-264 Board) - Sony DCR-TRV30E Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV30E:
Table of Contents

Advertisement

Available languages

Available languages

4-3. APC & AEQ Adjustment (VC-264 Board)
Mode
Playback
Signal
Recorded signal at "Preparations
before adjustments"
Measurement Point
Pin w; of CN009 (RF MON) (Note 1)
Ext. trigger: Pin qj of CN009 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is
"00"
Note 1: Connect a 75Ω resistor between Pin w; and Pin ql (GND) of
CN009.
75Ω resistor (Parts code: 1-247-804-11)
Note 2: The "AGC Center Level Adjustment" must have already been
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
3
33
08
4
5
3
01
07
6
3
02
7
3
03
8
Note 3: If the data is other than "00", adjustment has errors. Take an
appropriate remedial measures according to the errors referring to
the following table.
Data
Contents of defect
20
Perform re-adjustment. (Note 4)
30
The machine is defective
50
Perform re-adjustment. (Note 4)
60
The machine is defective
80
The machine is defective
Note 4: If this data is displayed twice successively, the machine is defective.
PB RF signal is stable
Pin w;
Pin qj
RadarW
RadarW
RadarW
Procedure
Playback the recorded signal at
"Preparations before
adjustments"
Set the data.
Set the data.
Confirm that the playback RF
signal is stable. (Fig. 5-3-5.)
Set the data, and press PAUSE button.
Check that the data changes
from "07" to "00" in about 20
seconds after pressing PAUSE
button.
Check that the data is "00".
(Note3)
Perform "Processing after
Completing Adjustments".
6.7 msec
Fig. 5-3-5.

4-4. Processing after Completing Adjustments

Order Page Address Data
1
2
30
2
3
33
3
0
01
5. PLL fo & LPF fo Fine Adjustment (VC-264 Board)
RadarW
RadarW
RadarW
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
3
01
3
3
02
4
3
03
5
0
01
Note1: If it is not satisfied, there are errors.
Note2: If the data of page: 3, address: 03 is other than "00", there are
errors. For the error contents, see the following table. (For the bit
values, refer to "5-4. SERVICE MODE", "4-3. 3. Bit value
discrimination".)
Bit value of page: 3,
address: 03 data
bit 2 = 1 or bit 3 = 1
bit 4 = 1 or bit 5 = 1
bit 6 = 1
5-48
Procedure
00
Set the data.
00
Set the data.
00
Set the data.
VTR stop
Arbitrary
Display data of page: 3, address: 02, 03
Adjustment remote commander
C
1F, 20, 22, 29
Data of page: 3, address: 02 is "00".
Data of page: 3, address: 03 is "00".
Procedure
01
Set the data.
30
Set the data, and press PAUSE button.
Check that the data changes to
"00" within 5 sec. (Note1).
Check that the data is "00".
(Note2)
00
Set the data.
Error contents
PLL fo fine adjustment is defective
PLL fo adjustment is defective
LPF fo is defective