Control panel settings
Changed settings
For increased security, change the following linked settings when "Enhanced
Security" is set to "ON".
"Admin. Setting" menu
"Security Setting" – "Security Details" –
"Password Rules"
"Security Setting" – "Security Details" –
"Prohibit Func."
"Security Setting" – "HDD Setting" –
"Overwrite Temp."
Note
The number of times for checking for "Prohibit Func." can be changed to
a number between one and three.
A changed setting cannot be changed when "Enhanced Security" is set
to "OFF".
When "Password Rules" is set to "Enable", a password that does not
meet the password rules is considered a failed attempt during authenti-
cation. For details on the password rules, refer to "Password Rules" on
page 4-47.
Note
When "Enhanced Security" is set to "ON", limitations are placed on the
user for the following operations.
When password authentication has failed the number of times specified
for "No. of Tries", the control panel can no longer be operated (authenti-
cation lock). If operation of the control panel is restricted, select "Prohibit
Func.", then "Release Setting", and then select the prohibited operations
to be allowed.
An application performing the write operation with SNMP v1/v2c cannot
be connected.
Write users using SNMP v3 must be authenticated.
This machine's counter data cannot be retrieved by PageScope Net Care
or PageScope VISUALCOUNT-MASTER.
C250P
Changed settings
Set to "Enable".
Set to "Mode 2" and three times or less for
checking.
Set to "Mode 2".