SNMP
Configuring SNMP Notification Recipients
STEP 1
STEP 2
STEP 3
Cisco 220 Series Smart Plus Switches Administration Guide Release 1.0.0.x
Use the Notification Recipients SNMPv1,2 page and the Notification Recipients
SNMPv3 page to configure the destination to which SNMP notifications are sent,
and the types of SNMP notifications that are sent to each destination (traps or
informs).
An SNMP notification is a message sent from the switch to the SNMP
management station indicating that a certain event has occurred, such as a link up/
down.
This section describes how to configure SNMP notification recipients and includes
the following topics:

Configuring SNMPv1,2 Notification Recipients

Configuring SNMPv3 Notification Recipients
Configuring SNMPv1,2 Notification Recipients
To define a recipient in SNMPv1,2:
Click SNMP > Notification Recipients SNMPv1,2.
Click Add to create an SNMPv1,2 notification recipient.
Enter the following information:
Server Definition—Select either By IP Address or By Name to define the
notification recipient.
IP Version—Select either Version 4 (IPv4) or Version 6 (IPv6) if the
notification recipient is identified by IP address.
Receiver IP—Enter the IP address or host name of where the traps are sent.
UDP Port—Enter the UDP port used for notifications on the recipient device.
Notification Type—Select whether to send Traps or Informs. If both are
required, two recipients must be created.
Timeout—Enter the number of seconds that the switch waits before re-
sending informs. The default is 15 seconds.
Retries—Enter the number of times that the switch resends an inform
request. The default is 3.
Community String—Select the SNMP community of the trap manager.