Brew Count Total
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock . . . (Factory set to 5º)
Press to select, < > to select desired setting (CBL 5, 15 or OFF), to set.
Cold Brew Lock
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is
within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew mes-
sage, however it will brew at any temperature.
Master Reset
Master Reset
Press to display Are You Sure?
Then < for Yes, > for No.
Brewer factory defaults are then reset.
Service Call (Phone number Factory set to 1-800-000-0000)
Service Call
Press to display number and change number or < to move place and EX to exit when complete This number will be displayed dur-
ing a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Access Code
Press to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when complete.
Banner Name (Factory set to Curtis)
Press to display current banner. Press < > to move place and EX to exit when complete. This feature allows up to 14 letters to
Banner Name
be programmed for company name or regional name. Programming all blanks disables Banner Name. Once the banner has been
programmed, the words will be displayed during normal operation, above the words Ready to Brew.
P-Maintenance (Factory set to OFF)
P-Maintenance
Press to Select, Set gallons brewed to indicate P-Maintenance. Press < > to adjust from Off to 3000 gallons. Press to exit.
Beeper On/Off (Factory set to ON)
Beeper On/Off
Press to display ON or OFF. Pressing either < > toggles between on and off. to set.
Pulse Brew (Factory set to OFF)
Pulse Brew
Press to select. Display will now show Select Button. Select desired Brew button to program. The next screen will prompt you to
On/Off
press < > to select OFF or one of four pulse patterns (A to E) .
Guidelines for Pulse Brew:
This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind
profile and water conditions, the five Pulse Brew options help "tune" or change the coffee flavor. Filter Pack type coffees typically
extract better with the A and B pulse setting. Decaffeinated coffees typically extract better with the B pulse setting. High-Yield coffees
typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste profile. There are
two additional settings (D and E) that allow you to manually set the ON TIME pulses and OFF TIME.
If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point. Cold Brew Lock and Pre-infusion disappears
from the list of program selections. When Pulse Brew is ON, Pre-Infusion disappears from the list of program selections.
Display Brew Time (Factory set to ON)
Display Brew
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When on, the Display Brew Time feature
Time
allows you to see the remaining time in the brew cycle counting down.
Drip-Out
Drip-Out Mode (Factory set to 2 min)
Mode
Press to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time counts up in 5
second increments. Press to set.
Exit
Exit
Press to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.
3