Download Print this page

Advertisement

Quick Links

Models Included
• D60GT
WARNING HOT LIQUID,
Scalding may occur.
Avoid splashing.
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
CAUTION: DO NOT
connect this brewer to hot
water. The inlet valve is
not rated for hot water.
CAUTION: When
cleaning, DO NOT use
powders, liquids, cleans-
ers, or any substance containing
chlorine. These products promote
corrosion, cause pitting of
stainless steel and will void the
warranty.
C
ISO 9001 REGISTERED
WILBUR CURTIS COMPANY
Montebello, CA 90640
W
ilbur
Service Manual, D60GT
Important Safeguards/Conventions
This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be performed by an autho-
rized Wilbur Curtis service center.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, do NOT open top or rear panel. No user serviceable parts inside. Repair should
be done only by authorized service personnel.
• Keep hands and other items away from hot parts of unit during operation.
• Never clean with scouring powders, bleach or harsh implements.
Conventions
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
Your Curtis G3 System is Factory Pre-Set and Ready to Go... Right from the Carton.
Following are the Factory Settings for your D60GT
Coffee Brewing Systems:
• Brew Temperature = 200°F
• Brew Volume = Set to dispensing vessel requirements (60 oz)
Generally there will never be a reason to change your G3 programming. However, should you need to make slight adjustments to meet
your brewing needs, programming instructions are provided later in this manual.
System Requirements:
• Water Source 20 – 90 PSI. Must have a minimum flow rate of ½ GPM (preferred flow rate is 1 gpm).
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
Equipment to be installed to comply with applicable federal, state, or local plumbing/electrical codes having jurisdiction.
SETUP STEPS
The unit should be level (left to right and front to back), located on a solid counter top. Connect a water line from the water filter to the
brewer. NOTE: Some type of water filtration device must be used to maintain a trouble-free operation. (In areas with extremely hard
water, we suggest that a sedimentary and taste & odor filter be installed.) This will prolong the life of your brewing system and enhance
coffee quality.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for
cleaning underneath.
2. This equipment is to be installed with adequate backflow protection to comply with applicable federal, state and local
codes..
3. Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and main-
tained in accordance with federal, state, and local codes.
1. A 3/8" NPT x 1/4" Flare elbow has been supplied for water line connection. Use adequate water tubing, sized to provide a minimum
of ½ GPM.
2. Connect the unit to an appropriate electrical power circuit.
3. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill. When the water level in the tank rises to
the correct volume, the heating element will energize automatically. G3 systems eliminate element burn-out due to an under-filled
heating tank.
4. The heating tank will require 20 to 30 minutes to reach operating temperature (200°F), indicated by the READY-TO-BREW light.
5. Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.
6. Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.
BREWING INSTRUCTIONS
1. Brewer should be ON (Confirm at rear toggle switch, then press ON/OFF button). Ready-to-Brew should be displayed.
2. Place a clean, empty decanter on brew deck.
3. Place a new filter in brewcone.
4. Pour ground
coffee into
brewcone.
C
C
urtis
ompany
5. Position
brewcone
into brew
rails.
, i
.
nC
6. Press
Brew
button.
1

Advertisement

loading

Summary of Contents for Curtis D60GT

  • Page 1 Important Notes/Cautions – from the factory Scalding may occur. Avoid splashing. Sanitation Requirements Your Curtis G3 System is Factory Pre-Set and Ready to Go… Right from the Carton. CAUTION: Please use Following are the Factory Settings for your D60GT this setup procedure...
  • Page 2: Program Menus

    Your Curtis ADS System is Factory Pre-Set for Optimum Performance. After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller. The control displays . Press ON/OFF button and the screen will display <D60GT> . After three seconds, is displayed. CURTIS CURTIS CURTIS FILLING Water will fill the tank (approximately 2-3 minutes depending on water flow rate). When the proper level is reached will appear on the CURTIS HEATING screen. It takes approximately 20 minutes to reach setpoint temperature of 200°F. Control will display when temperature reaches the setpoint (200°F). Unit is now ready to brew. CURTIS READY TO BREW To Go Into Programming Turn off (dark display) by pressing ON/OFF button (yellow). Press and hold BREW button (green) and then press and release ON/OFF button (yellow).
  • Page 3 Press  to select, < or > to select model. The selections are: ALPHA‑1, ALPHA‑2, ALPHA‑3/4/5, Airpot Brewer, Thermo-Alpha (for the D60GT). Press  to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly selected model.
  • Page 4: Illustrated Parts

    ILLUSTRATED PARTS...
  • Page 5: Parts List

    PARTS LIST Item Part No. Description Item Part No. Description 1 WC-58117 COVER, TOP D60GT 13A WC-3503 LEG, SCREW BUMPER (3/8”) 2 WC-2962 FITTING, SPRAYHEAD ASSY PLATED WC-3621-101 BREW CONE, UNIVERSAL 7.38” DIA. 2B WC-2977-101 FITTING, SPRAYHEAD ULTEM (OLDER UNITS) 14A WC-3316 BREW CONE, ASSY S.S. (OPTIONAL) 2A WC-2977 FITTING, SPRAYHEAD PLATED (OLDER UNITS) WC-6221 SCREEN, DRIP TRAY SS (OPTIONAL) 3 WC- 889* VALVE, DUMP LEFT 120V 12W WC-3765L* KIT, VALVE REPAIR (FOR WC-826 VALVE) 4 WC-37064* KIT, LABEL & UCM D500/D60GT CURTIS...
  • Page 6: Product Warranty Information

    Product Warranty Information The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply: 3 Years, Parts and Labor, from Original Date of Purchase on digital control boards.