• D1000GT
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
CAUTION: DO NOT
connect this brewer to hot
water. The inlet valve is
not rated for hot water.
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO., INC.
6913 West Acco Street
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800-421-6150
Fax: 323-837-2410
Service Manual – D1000GT Airpot Brewer
Important Safeguards & Symbols
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance
should be performed by an authorized Wilbur Curtis service technician.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside.
• Keep hands and other items away from hot surfaces of unit during operation.
• Never clean with scouring powders, bleach or harsh chemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
The Curtis G3 airpot brewer is Factory Pre-Set and Ready to Go... Right from the Box.
Following are the Factory Settings for Curtis airpot brewers:
• Brew Temperature = 200°F
• Brew Volume = Set to vessel requirements (75 oz).
System Requirements:
• Water Source 20 – 90 PSI (minimum flow rate of 1 GPM)
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
Setup Steps
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine
should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of 1 GPM.
NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be purged
from the cartridge prior to connection to equipment. In areas with extremely hard water, we highly
recommend the use of a Curtis approved water filter. For our full line of filters, please log on to www.wilbur-
curtis.com.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit
can be moved for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable federal, state and
local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized, installed
and maintained in accordance with federal, state, and local codes.
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the 'ON' position (located on the rear of
the unit), the water tank will begin to fill. When the water level in the tank reaches the probe, the heating
element(s) will turn on.
5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory
setting of 200°F). Where applicable, turn on the Universal Control Module (UCM). When the unit reaches
operating temperature, it will display "READY TO BREW".
For the latest specifications and information go to www.wilburcurtis.com
Technical Support: 1-800-995-0417 M-F 5:30 am - 4:00 pm PT
W
C
C
ilbur
urtis
o
Email: techsupport@wilburcurtis.com
., i
.
nC
1

Advertisement

loading

Summary of Contents for Curtis D1000GT

  • Page 1 WARNINGS – To help avoid personal injury Important Notes/Cautions – from the factory Sanitation Requirements Model • D1000GT The Curtis G3 airpot brewer is Factory Pre-Set and Ready to Go… Right from the Box. Following are the Factory Settings for Curtis airpot brewers: • Brew Temperature = 200°F • Brew Volume = Set to vessel requirements (75 oz). System Requirements: • Water Source 20 – 90 PSI (minimum flow rate of 1 GPM)
  • Page 2: Brewing Instructions

    Brewing Instructions 1. Brewer should be ON (Confirm at rear toggle switch, then press ON/OFF button). Ready to Brew on screen. 2. Open the lid on an empty airpot and place it on the brew deck. Be careful to center it under the brew cone. 3.
  • Page 3 Press  to display the Access Code number (the number range is 1 to 4). Press > or < to move the cursor. Press ex to exit when complete. Banner Name (Factory set to Curtis) Press  to display current banner. Press < > to move place and EX to exit when complete. This feature allows up to 14 letters to Banner Name be programmed for company name or regional name.
  • Page 4: Parts List

    Press  to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message will alternate; two seconds with Rinse Server Before Brewing, then Curtis READY TO BREW will appear for six seconds. Model Select (Factory set to D1000GT) Model Select Press  to select. Press > or < to toggle between D1000GT and D500GT 2Batch. Press ...
  • Page 5 Parts Diagram...
  • Page 6: Electrical Schematic

    Cleaning the Brewer Regular cleaning of the airpot brewer will maintain the highest quality coffee your equipment is capable of producing. Proper cleaning is essential to maintain that fresh, appealing look to your coffee service. 1. Turn off the brewer at the ON/OFF button on the control panel. Wipe any spills, dust or debris from the exterior surfaces, with a damp cloth.
  • Page 7 Electrical Schematic Dual Voltage...
  • Page 8: Product Warranty Information

    The warranty covers original equipment at time of purchase only. The Wilbur Curtis Co., Inc., assumes no responsibility for substitute replace- ment parts installed on Curtis equipment that have not been purchased from Wilbur Curtis Co., Inc. The Wilbur Curtis Co., Inc. will not accept any responsibility if the following conditions are not met.