Curtis D1000GT Service Manual

Curtis D1000GT Service Manual

Curtis d1000gt twin automatic airpot brewer

Advertisement

Model
• D1000GT
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
CAUTION: DO NOT
connect this brewer to hot
water. The inlet valve is
not rated for hot water.
WARNING HOT LIQUID,
Scalding may occur.
Avoid splashing.
To avoid temperature
drop when first brewing
coffee into the airpot,
preheat the airpot with hot water.
C
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO., INC.
6913 West Acco Street
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800-421-6150
Fax: 323-837-2410
W
Service Manual – D1000GT Airpot Brewer
Important Safeguards/Conventions
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be performed by an
authorized Wilbur Curtis service technician.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside.
• Keep hands and other items away from hot surfaces of unit during operation.
• Never clean with scouring powders, bleach or harsh chemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
The Curtis G3 airpot brewer is Factory Pre-Set and Ready to Go... Right from the Box.
Following are the Factory Settings for Curtis airpot brewers:
• Brew Temperature = 200°F
• Brew Volume = Set to vessel requirements (75 oz).
System Requirements:
• Water Source 20 – 90 PSI (minimum flow rate of 1 GPM)
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine should be consistent. Use
tubing sized sufficiently to provide a minimum flow rate of 1GPM.
NOTE: A water filtration system must be used to help maintain trouble-free operation. In areas with extremely hard water, we highly
recommend the use of a Curtis approved water filter. For our full line of filters, please log on to www.wilburcurtis.com. A water filtra-
tion system will greatly prolong the life of the unit and enhance the quality and taste of the product.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit can be moved
for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable federal, state and local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized, installed and main-
tained in accordance with federal, state, and local codes.
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the 'ON' position (located on the rear of the unit), the water tank will
begin to fill. When the water level in the tank reaches the probe, the heating element(s) will turn on.
5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory setting of 200°F). Where
applicable, turn on the Universal Control Module (UCM). When the unit reaches operating temperature, it will display "READY TO BREW"..

BREWING INSTRUCTIONS

1. Brewer should be ON (Confirm at rear toggle switch, then press ON/OFF button). Ready to Brew on screen.
2. Open the lid on an empty airpot and place it on the brew deck. Be careful to center it under the brewcone.
3. Place a new filter into the brewcone.
4. Pour the
proper
amount of
ground cof-
fee into the
brewcone.
For the latest specifications and information go to www.wilburcurtis.com
C
C
ilbur
urtis
ompany
5. Position the
brewcone
into brew
rails.
Technical Support: 1-800-995-0417 M-F 5:30am-4:00pm PT
Email: techsupport@wilburcurtis.com
, i
.
nC
6. Press the
BREW
button
to start
brewing.
1

Advertisement

Table of Contents
loading

Summary of Contents for Curtis D1000GT

  • Page 1: Brewing Instructions

    • To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside. • Keep hands and other items away from hot surfaces of unit during operation. • Never clean with scouring powders, bleach or harsh chemicals. Symbols WARNINGS – To help avoid personal injury Important Notes/Cautions – from the factory Sanitation Requirements Model The Curtis G3 airpot brewer is Factory Pre-Set and Ready to Go… Right from the Box. • D1000GT Following are the Factory Settings for Curtis airpot brewers: • Brew Temperature = 200°F • Brew Volume = Set to vessel requirements (75 oz). System Requirements: • Water Source 20 – 90 PSI (minimum flow rate of 1 GPM) • Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model. SETUP STEPS 1. The unit should be level (left to right - front to back), on a secure surface. CAUTION: Please use this setup procedure 2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine should be consistent. Use before attempting to use tubing sized sufficiently to provide a minimum flow rate of 1GPM.
  • Page 2: Program Menus

    To Go Into Programming Turn off (dark display) by pressing ON/OFF button (yellow). Press and hold BREW button (green) and then press and release ON/OFF button. Continue holding BREW button. Display will read , wait until is displayed Enter the 4-digit access code, the digits 1-4 correspond ENTERING PROGRAM ENTER CODE MODE – – – – to the buttons (see illustration below). The default code set at the factory is 1-2-3-4. Then will be displayed. PROGRAM MENUS < SELECT > All programming selections are performed with the three center buttons. The symbols below the buttons are: Scroll LEFT ...
  • Page 3 Service Call (Phone number Factory set to 1-800-000-0000) Service Call Press  to display number and change number or < to move place and EX to exit when complete This number will be displayed dur- ing a Heating system SENSOR ERROR or during a WATER ERROR. Access Code (Factory set to 1-2-3-4) Access Code Press  to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when complete. Banner Name (Factory set to Curtis) Press  to display current banner. Press < > to move place and EX to exit when complete. This feature allows up to 14 letters to Banner Name be programmed for company name or regional name. Programming all blanks disables Banner Name. Once the banner has been programmed, the words will be displayed during normal operation, above the words Ready to Brew. P-Maintenance (Factory set to OFF) P-Maintenance Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < > to adjust from Off to 3000 gallons. Press  to exit.
  • Page 4 Parts Diagram...
  • Page 5: Parts List

    Parts List Item № Part № Description Item № Part № Description WC-3418 BREW CONE,ASSY W/SPLASH POCKET WC-75285 TANK, COMPLETE D1000GT 220V WC-3316 BREW CONE, ASSY S.S. (OPTIONAL) WC-75284 TANK, COMPLETE D1000GT/H 120/220V DV WC-5421 COVER, TOP WC- 847* VALVE, INLET 2GPM WC- 889* VALVE, DUMP VALVE LEFT 120VAC 10W WC- 103* SWITCH, TOGGLE NON-LIT DPST 25A 125/250V WC-2962-101K KIT, FITTING SPRAYHEAD KYNAR WC-3763* KIT, VALVE REPAIR USE ON WC-889 /WC-817 WC- 817* VALVE, DUMP RIGHT 120V 12W WC-6221 GRID, DRIP TRAY AIRPOT (OPTIONAL) WC-67101 BRACKET, UCM WC-5310* TUBING, SILICONE, 5/16” I.D. ( 1 FT.) WC-37177* KIT, UCM & OVERLAY D1000GT WC-5502-01* KIT, PROBE WATER LEVEL W/NUT & O’RING...
  • Page 6 Electrical Schematic Dual Voltage...
  • Page 7 Cleaning the Brewer Regular cleaning of the airpot brewer will maintain the highest quality coffee your equipment is capable of producing. Proper cleaning is essential to maintain that fresh, appealing look to your coffee service. 1. Turn off the brewer at the ON/OFF button on the control panel. 2.
  • Page 8: Product Warranty Information

    Curtis equipment that have not been purchased from the Wilbur Curtis Company, Inc. The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under the following circumstances: 1) Improper operation of equipment: The equipment must be used for its designed and intended purpose and function.

Table of Contents