Installation; Installation Clearances - Napoleon GSST8N Installation And Operating Instructions Manual

Natural gas propane
Table of Contents

Advertisement

8

3.0 INSTALLATION

3.1

INSTALLATION CLEARANCES

C
A
INSTALLATIONS
CANADA
A
8 INCHES
B
12 INCHES
C
12 INCHES*
D
18 INCHES**
E
12 INCHES**
F
1 INCH
G
3 FEET
H
3 FEET
I
12 INCHES
J
6 FEET
K
12 INCHES
*
Recommended to prevent condensation on windows and thermal breakage.
**
It is recommended to use a heat shield and to maximize the distance to vinyl clad sof¿ ts.
***
This is a recommended distance. For additional requirements check local codes.
****
Three feet above if within 10 feet horizontally.
W415-0689 / C / 06.13.12
G
G
H
U.S.A.
8 INCHES
Clearance above grade, veranda porch, deck or balcony.
9 INCHES
Clearance to windows or doors that open.
12 INCHES*
Clearance to permanently closed windows.
18 INCHES**
Vertical clearance to ventilated sof¿ t.
12 INCHES**
Vertical clearance to an unventilated sof¿ t.
Clearance to an inside combustible corner wall or protruding
1 INCH
combustible obstructions. (vent chase, etc.)
Clearance to each side of the centre line extended above the metre/
3 FEET***
regulator assembly to a maximum vertical distance of 15 ft.
3 FEET***
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a
9 INCHES
combustion air inlet to any other appliance.
3 FEET****
Clearance to a mechanical air supply inlet.
12 INCHES*** Clearance under a veranda, porch, deck or balcony.
D E
F
B
I
K
J
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsst8p