SYMPTOM
Burner will not light,
ignitor sparks.
Ignitor will not spark.
SENSOR
ELECTRODE
1 /8"
GAP
CERAMIC
HIGH
BODY
VOLTAGE
IGNITION
CABLE
Remote wall switch
is in "OFF" position;
burner comes on.
PROBLEM
No gas at the burner.
Out of propane gas.
No spark at ignitor.
Spark gap is incorrect.
Wall switch is mounted
upside down.
Remote wall switch is
grounding.
Remote wall switch
wire is grounding.
Faulty wire.
TEST SOLUTION
-
Check that the manual valve is turned on.
-
Replace the valve.
-
Fill the tank.
-
Check the power source. (ie. fuse, circuit breaker)
-
Check that the wire is connected to both the ignitor
and the control module.
-
Check that the spark is not jumping to ignitor cover.
-
Replace the wire if the wire insulation is broken or
frayed.
-
Replace the electrode if the ceramic insulator is
cracked or broken.
-
Spark gap should be 0.125" (1/8" approx.) from the
electrode tip to the sensor tip.
-
Reverse.
-
Replace.
-
Check for ground (short); repair ground or replace
wire.
-
Replace.