Message listing

Operator Log Message
Background accessory changed
while powered up
Calibration failed
Calibration is suggested
Calibration succeeded
Calibration target is too narrow
Call Service
Check document preparation
Check imaging guides and lamps
Close pod and re-enable scanner
Document too dark to deskew
Document too long to rotate
Elevator too full, feed module
missing or broken
6-6
Following is an alphabetic list of messages and corrective actions you
can take if one of the following messages is encountered.
ID#
381
Background Accessory was changed while the scanner was
powered on.
• Turn the power off to the scanner, wait a few seconds and
power the scanner back on.
• If you get this message and you did not change the
Background Accessory, clean and calibrate the scanner.
108
• Try to calibrate the scanner again. Be sure you are using the
correct calibration target. See Chapter 3, "Calibrating the
scanner".
• Clean the imaging guides. See Chapter 5, Maintenance for
procedures.
• If the problem persists, call Service.
185, 585,
• It is suggested that you calibrate the scanner when the current
985
batch of documents has completed.
107
Informational message. The scanner has been successfully
calibrated.
331
The calibration target is too small. A 12- x 12-inch calibration
target is required for Image calibration.
• Calibrate the scanner again using the correct calibration target.
Many ID
A condition was detected that may require repair.
numbers
• Turn the power off to the scanner, wait a few seconds and
power the scanner back on.
• If the problem persists, call Service.
123
• Make sure the leading edges of the documents are aligned.
See Chapter 3, "Document preparation" for more information.
149, 549,
• Verify that the imaging guides are installed correctly. See
949
Chapter 5, Maintenance.
• Clean both sides of the imaging guides.
• If the pod is closed, and the message persists, call Service.
306
The pod may have been opened and not closed properly when
scanning was attempted.
• Be sure the pod is completely closed.
143, 543,
Informational message. The scanner was unable to find the
943
document edges to determine the skew angle.
• The document is too dark.
• The image is too large.
46, 446,
The scanned document was too long to rotate. Scanning was
846
stopped.
• Locate this document and rescan it with a lower resolution or
with Rotation turned off.
297
• There is too much paper in the elevator tray and it is holding
the feed module up. The elevator tray capacity is 500 sheets.
Remove some documents from the elevator tray.
• The feed module is not installed properly. See Chapter 5,
Maintenance, for correct installation procedures.
• If the problem persists, call Service.