Following is an alphabetic list of messages and corrective actions you
can take if one of the following messages is encountered.
ID#
381
319
106, 331 • Clean the imaging guides. See Chapter 5, Maintenance for
105, 342 Informational message. The scanner has been successfully
Many ID
numbers
184
90
123, 135,
81
149, 178,
139
294
manuals search engine
Operator Message
The Background Accessory was changed while the scanner was
powered on.
• Turn the power off to the scanner, wait a few seconds and
power the scanner back on.
• If you get this message and you did not change the
Background Accessory, clean the scanner.
Some device on the FireWire bus was unplugged/plugged in.
• Check that all FireWire connectors are securely fastened.
procedures.
• Try to calibrate the scanner again. Be sure you are using the
correct calibration target. See Chapter 3, "Calibrating the
scanner".
• The calibration target is too small. A 12- x 12-inch calibration
target is required for image calibration.
• Calibration target is too narrow.
• If the problem persists, call Service.
calibrated.
A condition was detected that may require repair.
• Turn the power off to the scanner, wait a few seconds and
power the scanner back on.
• If the problem persists, call Service and provide the ID number
of the error.
Both a front and rear print head is installed in the scanner. Only
one print head can be installed at one time.
• Remove one of the print heads.
The White Background Accessory is installed in the scanner
while the scanner is trying the calibrate.
• Remove the White Background Accessory before calibrating
the scanner.
• The gap between your documents is too small.
• Make sure the leading edges of the documents are aligned.
See Chapter 3, "Document preparation" for more information.
• Check the condition of your feed module and separation roller
tires and your pre-separation pad. Clean and replace if
necessary.
• Verify that the imaging guides are installed correctly. See
Chapter 5, Maintenance.
• Clean both sides of the imaging guides and lower glass plate
between the lamps.
• Check that the white patch on the imaging guides is clean and
in good condition.
• If the problem persists, call Service.
The lower imaging guide is dirty or there may be a small piece of
paper in the imaging guide area.
• Clean the imaging guides. See Chapter 5, Maintenance for
procedures.