Replacement
procedures
Replacing the feed
module or feed module
tires
5-12
This section provides procedures for replacing the following parts. Use
the list below as a guideline for frequency of replacement.
• Feed Module tires and Separation Roller tires — tire life will vary
depending upon paper types, environment and cleanliness. Nominal
tire life will be approximately 250,000 documents; results will vary.
Degradation of feeder performance, multiple feeds, stoppages, etc.
indicate a need to change tires. Change all the tires on the feed
module and separation roller at the same time.
• Feed Module and Separation Roller — it is recommended that you
install a new feed module and separation roller approximately every
4th tire change. Install a new feed module and separation roller at the
same time.
• Pre-separation Pad — it is recommended that you change the pre-
separation pad approximately every 250,000 documents.
• Imaging Guides — replace when the imaging guides are heavily
scratched and defects show in the image.
To replace the feed module or feed module tires:
1. Remove the output tray.
2. Lift up the printer access cover.
3. Open the pod.