Skew Monitor; Momentary Flag - Kodak 7520 User Manual

Document scanner
Hide thumbs Also See for 7520:
Table of Contents

Advertisement

Code
Function Code Name
F70
Length Monitor On/Off
F71
Omit Length Monitor on the
Next Document Only
F72

Skew Monitor

F73
Latched Flag On/Off
F74

Momentary Flag

F75
Footswitch Confirmation
Tone
A-61140 January 2000
Allows you to turn the length monitor on or off. The length
monitor checks the length of the documents scanned
against the predefined minimum/maximum allowable
lengths. Messages and/or confirmation tones alert you if
the document is shorter or longer than the predefined
length.
Allows you to omit length checking on the next document
scanned. Length monitoring will resume on subsequent
documents. Enter 1 to turn on or 0 to turn off, then press
Enter.
Allows you to turn skew detection on or off which monitors
the amount of skew using predefined skew angle(s).
Allows you to set a flag in the image headers which alerts
the host system that this document, and those which
follow, are of special interest. The flag will remain activated
for every document until it is turned off. Enter 1 to turn on
or 0 to turn off, then press Enter.
Allows you to set a flag in the image header which alerts
the host system that this document is of special interest.
This flag is set only for that one document. Enter 1 to turn
the momentary scanning flag on, then press Enter.
Allows you to turn the confirmation tone on or off which
informs you when the Footswitch is pressed and/or
released. Enter 1 to turn on or 0 to turn off, then press
Enter.
Description
4-7

Advertisement

Table of Contents
loading

Table of Contents