YASKAWA VS mini C Series Instruction Manual page 47

Ultra-compact all digital inverter advanced function type
Hide thumbs Also See for VS mini C Series:
Table of Contents

Advertisement

Terminal
function
at 3-wire sequence
selection
RUN SW
MS mini
STOP SW INO CONTACT)
INC CONTACT)---_SFI Run command
(Flun when "'closed'*l
SR Stop c ommand
(Slop when "oPen")
__/DIREV
..... te_tion
PWD r un whe_ " c_en"
REV r uth w hen "'closed" J
•LOCAL/REMOTE
select (setting:
14)
Selects operation
reference
by the digital
operator
or by the control
circuit
terminal.
LOCAL/REMOTE
selecl
is available
only during stop.
Open : Run according
to the setting
of operation
mode
selection
(n02).
Closed
: Run by frequency
reference
and run command
from
the digital
operator.
(Example)
Set n02 to 3 or 5.
Open
: Run by frequency
reference
from
control
circuit
terminal
FR
and run command
from control
circuit
terminals
SF, SR.
Closed
: Run by frequency
reference
and run command
from
the digital
operalor.
• UP/DOWN
command
(selling: nO8 = 15)
With the FWD
(REV)
run command
entered,
accel/decel
is enabled
by
inputting
the UP or DOWN
signals
to control
circuit
terminals
$2 and $3
without
changing
the frequency
reference,
so that
operation
can
be
performed
at the desired
speed.
When
UP/DOWN
commands
are
speci6ed
by nO8, any function
set to nO7 becomes
disabled;
leradnal
$2
becomes
an input
terminal
for the UP command
and terminal
$3 for the
DOWN
command.
Control Circuit Terminal $2
(UP command)
Closed Open
Open Closed'
Control Circuit Terminal $3
(DOWN command)
Open
Closed Open
Closed
Operation Status
Accel
Decel
Hold
Hold
47