Figure 22-6 Menu 24.12 - Hardware Monitor (Ves-1012); Table 22-5 Menu 24.12 - Hardware Monitor - ZyXEL Communications VES-1000 Series User Manual

Vdsl-ethernet switch
Hide thumbs Also See for VES-1000 Series:
Table of Contents

Advertisement

VES-1000 Series Ethernet Switch
FIELD
Temperature (C)
There are three temperature sensors inside the VES. Each sensor is
capable of detecting and reporting if the temperature rises above the
threshold of 65 degrees centigrade. Temp 1 refers to the first temperature
sensor.
Current
This shows the current temperature in degrees centigrade at this sensor.
Max
This field displays the maximum temperature measured at this sensor.
Min
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Status
This field displays "Normal" for temperatures below the threshold.
Fan speed
A properly functioning fan is an essential component (along with a
(RPM)
sufficiently ventilated, cool operating environment) in order for the VES-1012
(VES-1012 only)
switch to stay within temperature thresholds. Each fan has a sensor that is
capable of detecting and reporting if the fan speed falls below the threshold
of 4000 RPM.
Current
This field displays this fan's current speed in Revolutions Per Minute (RPM).
Max
This field displays this fan's maximum speed measured in Revolutions Per
Minute (RPM).
Min
This field displays this fan's minimum speed measured in Revolutions Per
Minute (RPM).
Threshold
This field displays the minimum speed at which a normal fan should work.
Status
"Normal" indicates that this fan is functioning above the minimum speed.
Voltage (V)
The power supply for each voltage has a sensor that is capable of detecting
and reporting if the voltage falls out of the tolerance range.
22-6
Menu 24.12 - Hardware Monitor
Temperature(C)
Current
TEMP1
33.0
TEMP2
31.5
TEMP3
46.5
Fan speed(RPM)
Current
FAN1
8083
FAN2
8181
FAN3
7941
FAN4
7803
Voltage(V)
Current
2.0
2.00
2.5
2.53
3.3
3.28
5.0
5.06
15.0
14.96
-5.0
-5.00
COMMANDS:r-Reset status

Figure 22-6 Menu 24.12 - Hardware Monitor (VES-1012)

Table 22-5 Menu 24.12 - Hardware Monitor

Max
Min
34.0
28.0
32.5
28.0
47.5
36.0
Max
Min
8231
7848
8282
7670
8035
7500
8083
7758
Max
Min
2.02
1.98
2.53
2.51
3.28
3.26
5.06
5.02
15.08
14.84
-5.00
-5.00
Press Command:
ESC-exit
DESCRIPTION
Threshold
Status
65.0
Normal
65.0
Normal
75.0
Normal
Threshold
Status
4000
Normal
4000
Normal
4000
Normal
4000
Normal
Tolerance(%) Status
10
Normal
5
Normal
5
Normal
10
Normal
5
Normal
5
Normal
System Maintenance 2
EXAMPLE
Temp1
35.0
37.0
34.0
65.0
Normal
7673
7803
7417
4000
Normal
V2.0