Installing Or Replacing A Device In The Optical Drive Bay - Lenovo ThinkStation P500 Hardware Maintenance Manual

Machine types: 30a6, 30a7, 30a8, and 30a9
Hide thumbs Also See for ThinkStation P500:
Table of Contents

Advertisement

1. Align the plastic boards on the top and bottom sides of the direct cooling air baffle with the small gaps
1
in the computer chassis.
Figure 15. Installing the direct cooling air baffle
2. Push the direct cooling air baffle in until it is placed firmly in position.
Note: If necessary, adjust the position of the direct cooling air baffle slightly to avoid the interference
from other components in the chassis.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation or replacement, go to "Completing the parts replacement" on page 183.

Installing or replacing a device in the optical drive bay

Attention: Do not open your computer or attempt any repair before reading and understanding the Chapter
1 "Read this first: Important safety information" on page 1.
The optical drive bay of your computer supports the following devices:
• Optical drive
• Flex module
• Front-access storage enclosure
The following instructions on how to install or replace an optical drive also apply to the other two devices.
To install or replace an optical drive, do the following:
1. Remove all media from the drives and turn off all attached devices and the computer. Then, disconnect
all power cords from electrical outlets and disconnect all cables that are connected to the computer.
2. Remove the computer cover. See "Removing the computer cover" on page 111.