Wiring - Z-Wave ZTS-110 User Manual

Z-thermostat
Hide thumbs Also See for ZTS-110:
Table of Contents

Advertisement

Wiring

- Be sure the operation mode is OFF
and Fan selection is Fan Auto
- Wire the proper cables at the terminal
block according to the circuit diagram
- Afterward, push all cables back into
the wall
- Do not use metal conduit or of cable
provided with a metal sheath
- Recommends adding fuse or
protective device in the line circuit
Important!
If you will be powering the ZTS-110 with 24Vac:
Connect the "24Vac Common" (typically the black wire/terminal) and "24Vac
Power" (typically the Red wire/terminal) from the HVAC system to the ZTS-110
HVAC System terminal block "C" and "RH" or "RC" terminals (see the following
explanation, these may be jumpered together).
Common or Split Transformer Systems:
Most HVAC systems have a common heating and cooling transformer. You must
insert a jumper wire to tie the RH and RC inputs together for this configuration. If
you have a system with separate heating and cooling transformers, do not insert a
jumper wire between RC and RH.
When wiring split systems, wire the heating systems "24Vac Power" (red wire) to
the ZTS-110 "RH" terminal, and wire the cooling systems "24Vac Power" to the
ZTS-110 "RC" terminal. Also wire the cooling systems "24Vac Common" to the
ZTS-110 "C" terminals.
Note: Do not split RC/RH for Heat Pump systems!
Figure 4. Non-heat pump (Standard Gas or Electric) HVAC system wiring
O
B
Brown
W2
White
W1
Green
G
Yellow
Y
RC
Red
RH
Black
C
Terminals
Cool changeover (heat pump)
Heat changeover (heat pump)
2nd Stage heater
1st Stage heater
Fan
Compressor
24Vac Power for Cooling
24Vac Power for Heating
24Vac Common
Standard HVAC System
W2 - 2 stage heater
nd
J2
W1 - 1 stage heater
st
G - Fan
Y - Compressor
R - 24Vac Power
C - 24Vac Common
7
Figure 5. Heat pump HVAC system wiring
Symbol
O
O
B
B
W2
W2
W1
W1
G
Y
G
RC
RH
Y
C
RC
RH
C
Figure 6. Non-heat pump 2-wires system wiring
O
B
W2
W1
G
Y
RC
RH
C
Thermostat should be powered by batteries and support heating control only.
Figure 7.Heat pump 2-wires system wiring
O
B
W2
W1
G
ELECTH
Y
RC
RH
HPUMP
C
Thermostat should be powered by batteries and support heating control only.
For heat pump output, there is a 3 minutes off time for heat pump protection.
Heat Pump HVAC System
Orange
O - Cool changeover (heat pump)
Blue
B - Heat changeover (heat pump)
Brown
W2 - 2 stage heater
nd
Green
G - Fan
Yellow
Y - Compressor
Red
R - 24Vac Power
Black
C - 24Vac Common
White
W1 - 1 stage heater
st
Red
R - 24Vac Power
Yellow
Y - Compressor
Red
R - 24Vac Power
8
ELECTH
HPUMP
J2
ELECTH
HG
HPUMP
HE
J2
J1
ELECTH
HG
HPUMP
HE
J2
J1