Filter Counter; Short Cycle Start Up Protection; Energy Saving Mode; Z-Wave Setup And Operations - Z-Wave ZTS-110 User Manual

Z-thermostat
Hide thumbs Also See for ZTS-110:
Table of Contents

Advertisement

Filter Counter

Step
Procedure / Description
Press and hold "Fan" key for 2 seconds to
check the filter counter.
1
The "usage hours" will be shown on screen.
Press and hold "Prog" key for 2 seconds to
2
reset the filter counter after replace a new
filter.
Press and hold "Mode" key to set the alert
time for the filter usage. "Target" icon will be
shown on screen and flashing.
Press "UP" or "Down" to set the alert time.
(Range from 500 to 4000 Hours Step size
3
is 100hrs)
Press "Prog" key to confirm the setting and
go back to filter counter page.
Press "Home" key once to go back to the
Home page.
FILTER icon will be shown on the screen at
4
Home page when the usage hours were
reached to set time.

Short Cycle Start Up Protection

To protect the compressor / Heat pump, those outputs forced off until 3minutes
count down finished. Those outputs can be activated according to the room
temperature after 3 minutes.
System
Non Heat pump system
Heat pump system
LCD indication
HR
FILTER
HR
FILTER
HR
FILTER
TARGET
MO
WAKE
AM
PROG ON
FILTER
FAN AUTO
Output
Compressor
1st stage heat and compressor
25

Energy Saving Mode

User can enable/disable energy saving mode by using Z-Wave BASIC set
command only. (you may refer to the Z-Wave primary controller UI for it)
=> Enable energy saving mode
Basic set value = 0x00 (off)
(energy saving mode will be mapped to off mode)
=> Disable energy saving mode
Basic set value = 0xFF (Resume)
(comfort mode will mapped to resume mode)

Z-Wave Setup and Operations

Setting FLiRS or Always Listening mode
- Setting to Z-Wave FLiRS mode with batteries as power source
ZTS-110 will self-configure to FLiRS mode if it is powered by batteries or
powered by batteries first then applied with 24Vac before Z-Wave inclusion.
FLiRS mode is targeted for battery operated applications and will enter sleep
mode frequently in order to save battery life. ZTS-110 can't act as a repeater in
this mode. The response to Z-Wave command is not as quick as Always
Listening Device. Normally there is 1-2 seconds latency on response, you
should avoid sending commands to ZTS-110 too frequently.
- Setting to Z-Wave Always Listening mode with 24Vac as power source
ZTS-110 will self-configure to Always Listening Mode if it is powered by 24Vac or
COOL
powered by 24Vac first then applied with batteries before Z-Wave inclusion.
Always Listening mode is targeted for AC power operated applications and it can
act as a repeater which will re-transmit the RF signal to ensure that the signal is
received by its intended destination by routing the signal around obstacle and
radio dead spots. The response to Z-Wave command is immediate.
26

Advertisement

Table of Contents
loading

Table of Contents