FCC Notice

This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Notice : Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user authority to operate the equipment.
Warnings
- Do not modify the unit in any way.
- Risk of fire.
- Risk of electrical shock.
- Risk of burns.
- Do not dispose of electrical appliances and unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available.
- There is no user serviceable parts in this unit.
Caution
- Risk of explosion if battery is replaced by an incorrect type.
- Dispose of used batteries according to the instructions.
Printed in China
F820-8031-0003
39
ZTS-110
Z-Thermostat
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Z-Wave ZTS-110

  • Page 1: Fcc Notice

    FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: ZTS-110 (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that Z-Thermostat may cause undesired operation.
  • Page 2: Table Of Contents

    Setup and Operations Product Overview Also, you can use the ZTS-110 to control / check your room temperature by smart Description of Function Keys phone or PC while you are at home or outside through Z-Wave gateway.
  • Page 3: Features List

    Features List Glossary HVAC System Type Compatible: Devices and nodes are all terms to describe an individual Z-Wave - Standard (gas/electric) or Heat Pump Device or Node device. These are all interchangeable when setting up your Z-Wave Multistage System Compatible: network.
  • Page 4: Physical Installation And Wiring

    Physically Installing the Thermostat - Turn off ZTS-110 and the electronic devices (e.g. heater, cooler) which will 1. Open the ZTS-110 by pulling the two sections apart (Figure 2). Use the fingertips be connected and the electric source before installation and maintenance.
  • Page 5: Wiring

    Thermostat should be powered by batteries and support heating control only. When wiring split systems, wire the heating systems "24Vac Power" (red wire) to the ZTS-110 "RH" terminal, and wire the cooling systems "24Vac Power" to the Figure 7.Heat pump 2-wires system wiring ZTS-110 "RC"...
  • Page 6: Jumper Settings For Electh-Hpump And He-Hg

    Event mode Inclusion indication Battery low indication You must ensure that these pins are set correctly for your system. The pin location is shown in the following diagram which is located at back side of ZTS-110. Jumper Function Description WAKE Time...
  • Page 7: Activate/Deactivate Easy Mode

    Activate/Deactivate Easy Mode Note: If you deactivated the Easy mode, please refer to Setting Mode for the temperature The ZTS-110 is default with Easy mode, below illustrates the functions of Easy scale selection. mode: - Active functions: Change Mode, change Fan mode and Temperature Scale...
  • Page 8 - Advanced Recovery Mode Press "Prog" key once to confirm the setting EASY mode is deactivated and it will go to swing setting. - Support full functions at local and Z-Wave control Press Up/Down key to set the swing setting. SWING (Range is from 0.5 C to 2 C or 1 F to 4 F )
  • Page 9 COOL Mode: thermostat controls the temperature according to the following Step Procedure / Description LCD indication diagram Output Set point Press "Prog" key once to confirm the setting and it will go to Advanced Recovery setting. RECOVERY Press Up/Down key to enable/disable Advanced Recovery Mode.
  • Page 10: Change Mode

    Change Mode Change Fan Mode Note: In Heat mode =>it displays "HEAT" if ELECTH is selected during jumper Step Procedure / Description LCD indication setting. Press "Fan" key once to change the Fan => it displays "HEAT PUMP" if HPUMP is selected during mode: jumper setting.
  • Page 11: Override/Permanent Override

    Setting Schedule Note: Override/Permanent Override is only available in HEAT, COOL or AUTO Below are the recommended settings for different schedule scenarios: mode. ZTS-110 Schedule scenarios ZTS-110 schedule Remark Easy mode setting Step Procedure / Description LCD indication Gateway controller...
  • Page 12 Step Procedure / Description LCD indication Step Procedure / Description LCD indication MO TU WE TH FR MO TU WE TH FR WAKE Press and hold "UP" and "DOWN" key for 2 seconds to disable / enable event during the time setting. Press and hold "Prog"...
  • Page 13: Battery Low Indication

    Procedure / Description LCD indication Procedure / Description LCD indication The Advanced Recovery feature allows ZTS-110 thermostat will detect the battery WAKE heating and cooling systems to gradually level every 30 minutes; Battery low icon will recover from an energy-saving set point...
  • Page 14: Filter Counter

    FLiRS mode is targeted for battery operated applications and will enter sleep Press "Prog" key to confirm the setting and mode frequently in order to save battery life. ZTS-110 can't act as a repeater in go back to filter counter page.
  • Page 15: Check Flirs / Always Listening Mode In Zts-110

    Remark: unit is in Always Listening mode and is - If you are using battery and somehow it is in Z-Wave Always Listening Mode, or included into Z-Wave network. if you are using battery as back up, and the AC power is down, the battery will drain very fast (battery will only survive 3-5 days).
  • Page 16: Support For Association Groups

    Association group Association group_1 Association group_2 - After ZTS-110 is included to Z-Wave network, it will stay in Easy mode by default. (Heat pump) (Compressor) Mode - You can enable or disable Easy mode by local "Setting Mode" or Z-Wave parameter number 8.
  • Page 17: Z-Wave Configuration Parameters

    Different user has different preferred settings of their thermostat, you may use the or controller can be assigned in this association group) below configuration parameters to change settings of corresponding functionality. ZTS-110 will trigger AUTO report function if one of below status is changed. Functions Parameter No.
  • Page 18 Parameter No. Parameter value range Parameter No. Parameter value range Functions Functions Temperature offset value. 0 (0x00) = disable AUTO report if room Formula: Display temperature temperature is different from last report. = sensor reading value + offset value Trigger AUTO report AUTO report if room temperature is different from (unit = degree F) if room temperature...
  • Page 19: Reset Zts-110 To Factory Default Settings

    The following data will be reset to default: Q Can I use 2 or more ZTS-110 in my house? What is the max. units if yes? 1. Clock : 12:00am A Yes and it is very depends on the capability of gateway / controller. For example, 2.
  • Page 20: Technical Specifications

    170g (Batteries excluded) Checking Accessories After opening the cover of the packaging box, check that the following accessories are included. - ZTS-110: Z-Thermostat - AA batteries x 4pcs (optional) - Screw + Wall Anchor x 4pcs - User Manual - RC/RH jumper wire x 1pc...