Association group_3: (Auto report)
- Association group_3 is used to report status change to gateway. (Only gateway
or controller can be assigned in this association group)
ZTS-110 will trigger AUTO report function if one of below status is changed.
I. Operation mode (Off, Heat, Cool, Auto)
II. Operation state (Heat on or off, Cool on or off)
III. Fan mode (Auto, Auto low)
IV. Fan state (Fan on or Fan off)
V. Heat set point (report in precision 1 after decimal, e.g. 21.1 C )
VI. Cool set point (report in precision 1 after decimal, e.g. 23.3 C )
VII. Current room temperature (report in precision 1 after decimal, e.g. 24.0 C)
(It will trigger room temperature report if there is 4 F or 2 C (default) differ from
last report. You can change this setting by set the configuration parameter)
Note: Total 5 devices (nodes) can be assigned in total 3 association groups. Below
table lists out the devices (nodes) allocations in the 3 association groups.
No. of Node ID in
Case No.
Association group_1
Case 1
4
Case 2
3
Case 3
2
Case 4
1
Case 5
0
Important: Please do not associate heat pump and compressor devices in same
association group because heat pump and compressor device cannot be turned on
simultaneously!
Association Groups setting example (case 3):
F-BW8041 (ZFM-80)
F-BW8041 (ZFM-80)
(Node ID-A)
(Node ID-B)
F-BW8041 (ZFM-80)
F-BW8041 (ZFM-80)
(Node ID-C)
(Node ID-D)
o
o
o
o
No. of Node ID in
No. of Node ID in
Association group_2
Association group_3
1 (AUTO report)
0
1 (AUTO report)
1
1 (AUTO report)
2
1 (AUTO report)
3
1 (AUTO report)
4
Association group_1
for Heat Pump
Association group_2
F-BW8031
for Compressor
(ZTS-110)
Association group_3
for Auto report to
gateway
Z-Wave Gateway
(Node ID-E)
31

Z-Wave Configuration Parameters

Different user has different preferred settings of their thermostat, you may use the
below configuration parameters to change settings of corresponding functionality.
Functions
Swing
o
Differential
Set filter counter
Report filter counter
(read only)
Scale of temperature
Upper limit of set
point (A)
Lower limit of set
point (B)
Easy mode
Time format
Repeat basic set
counter
(Association Group
A and B only)
Parameter No.
Parameter value range
o
1 (0x01) = 1 F / 0.5 C
2 (0x02) = 2 F / 1.0 C (default)
o
1 (0x01)
o
3 (0x03) = 3 F / 1.5 C
o
4 (0x04) = 4 F / 2.0 C
o
1 (0x01) = 1 F / 0.5 C
2 (0x02) = 2 F / 1.0 C (default)
o
2 (0x02)
o
3 (0x03) = 3 F / 1.5 C
o
4 (0x04) = 4 F / 2.0 C
500 (0x01F4) to 4000 (0x0FA0) hours
3 (0x03)
Default = 500 (0x01F4) hours
Resolution = 100 (0x0064) hours
4 (0x04)
0 (0x0000) to 9999 (0x270F) hours
o
0 (0x00) = C
5 (0x05)
1 (0x01) = F (default)
o
(A) available range:
o
Unit in Celsius ( C):
A = (B+2)min. ~ (37.0 C) max.
6 (0x06)
o
Unit in Fahrenheit ( F):
A = (B+4)min. ~ (99.0 F) max. (default = 99.0 F)
(B) available range:
o
Unit in Celsius ( C):
o
o
5.0 C to 35.0 C
7 (0x07)
o
Unit in Fahrenheit ( F):
41.0 F to 95.0 F (default = 41.0 F)
o
o
0 (0x00) = Disable
8 (0x08)
1 (0x01) = Enable, default
0 (0x00) = 24 hours
9 (0x09)
1 (0x01) = 12 hours (am / pm), default
Value(X): 0 (0x00), 3 (0x03) to 255 (0xFF)
0 (0X00) = Disable, default
10 (0x0A)
3 (0x03) to 255 (0xFF) minutes
(Thermostat sends "Basic Set" command to its
association node repeatedly in every X minutes)
32
o
o
o
o
o
o
o
o
o
o
o
o