Check Flirs / Always Listening Mode In Zts-110 - Z-Wave ZTS-110 User Manual

Z-thermostat
Hide thumbs Also See for ZTS-110:
Table of Contents

Advertisement

Important:
Please note the below scenarios for power applying because it will affect the battery
life if the steps are not correct (this is also mentioned at Physical Installation and
Wiring section in this user manual):
a) If it is powered by batteries or powered by batteries first then applied with
24Vac before Z-Wave inclusion, ZTS-110 will self-configure to FLiRS mode
which will save battery life by sleeping.
b) If it is powered by 24Vac or powered by 24Vac first then applied with batteries
before Z-Wave inclusion, ZTS-110 will self-configure to Always Listening Mode
which will not sleep.
c)
After inclusion process, ZTS-110 will not detect power source and not allow
changing operation mode. You must perform exclusion process first if need to
change Z-Wave operation mode.
d) After Z-Wave inclusion process, if you reset ZTS-110 to default while both
24Vac and batteries are applied, ZTS-110 will take 24Vac as primary power
source and self-configure to Always Listening Mode, because reset to default
process will automatically exclude ZTS-110 from the Z-Wave network. You
should disconnect the power source and re-apply the power so ZTS-110 can
detect the power source type and self-configure to corresponding mode.
Remark:
- If you are using battery and somehow it is in Z-Wave Always Listening Mode, or
if you are using battery as back up, and the AC power is down, the battery will
drain very fast (battery will only survive 3-5 days).
- Regardless the FLiRS mode or Always Listening Mode, the setup and
operations are same, and you can also use local control while is it included to Z-
Wave network.
27

Check FLiRS / Always Listening mode in ZTS-110

Procedure / Description
During normal operation, press and keep
holding the keys on "Fan" + "Mode" + "Prog"
for 3 seconds.
(The unit will resume to normal operation
after released all keys.)
- If the LCD displays "bt", the unit is
detected to be FLiRS mode if it will be
included into Z-Wave network;
- If the LCD displays "AC", the unit is
detected to be Always Listening mode if it
will be included into Z-Wave network;
- If the LCD displays "bt" + "RF icon", the
unit is in FLiRS mode and is included into
Z-Wave network;
- If the LCD displays "AC" + "RF icon", the
unit is in Always Listening mode and is
included into Z-Wave network.
Note:
After Z-Wave inclusion process, if you reset ZTS-110 to default while both 24Vac
and batteries are applied, ZTS-110 will take 24Vac as primary power source and
self-configure to Always Listening Mode. If you are using battery as back up, and
the AC power is down, the battery will drain very fast, battery will only survive 3-5
days.
Z-Wave Add (Include) / Delete (Exclude) into/from Z-Wave network
Add (Include) ZTS-110 to Gateway / Controller Z-Wave
network
Symbol
Inclusion and Exclusion Mode Key Description
Add (Include) / Delete (Exclude)
LCD indication
28

Advertisement

Table of Contents
loading