Setting the Wired Remote Controller Options
Switch
Switch OFF
No.
SW1 Cooling and Heating
Allow wireless remote
SW2
controller
Master remote
SW3
controller
SW4 Temperature display : °C
Use the indoor unit
Temperature Sensor for the
SW5
indoor unit control
-
SW6
SW7 Auto mode enable
SW8
-
Default settings
��� ��� ��� ��� ��� ��� ��� ���
�
� � ��� � � � �
After changing the setting of PCB, make sure to initialize
the system.
- To initialize the system, press the
at the same time for 5 seconds.
If the indoor unit does not support SW5 and SW6
options, indoor unit temperature sensor will be used
regardless of the settings.
You can check the wired remote controller DIP switch
settings in menu 15 of additional functions. (Refer to
page 29)
- You can check it without disassembling the product.
Switch ON
Cooling Only
Disable the wireless remote
controller
Slave remote controller
Temperature display : °F
Use the wired remote
controller Temperature
Sensor for the indoor unit
control
Use the average of the
indoor unit sensor and the
wired remote controller
sensor for the indoor unit
control
Auto mode disable
-
,
buttons