KVH Industries TracVision G6 Technical Manual page 143

Satellite tv system
Hide thumbs Also See for TracVision G6:
Table of Contents

Advertisement

TracVision G6 Technical Manual
Figure F-2
Optional 6-70 V Stepper Voltage
Converter Wiring Diagram
Interface Box
Terminal
1
2
3
4
5
negative
6
logic
7
8
9
10
positive
logic
11
12
13
14
6-70 VDC input from converter power supply
The step supply is internally fused at 1 amp. Step output lines are opto-isolated from step input lines.
152
Function
Step Line 1
Step Line 2
Step Line 3
OV Common
Step O/P Line 1 -VE Switch Line (Open Drain)
Step O/P Line 2 -VE Switch Line (Open Drain)
Step O/P Line 3 -VE Switch Line (Open Drain)
+VE Supply Out
-VE Supply Out
Step O/P Line 3 +VE Switch Line (Open Drain)
Step O/P Line 2 +VE Switch Line (Open Drain)
Step O/P Line 1 +VE Switch Line (Open Drain)
Step Supply -VE
Step Supply +VE (15-70 VDC)
4
3
2
1
Core Color
Interface Connector
Terminal Number
Red
23
Yellow
22
Green
21
Blue
24
Fuse 1A
Fuse 1A
Load
Load
Load
Load
Load
Load
14
13
12
11
10
9
8
7
6
5
54-0161

Advertisement

Table of Contents
loading

Table of Contents