Performance Specifications
TracVision G6 GyroTrac
Environmental Specifications
128
A.2 GyroTrac Compass
Performance Data
Table A-4
Accuracy
Repeatability
Resolution
Tilt angle/pitch & roll range
Rate gyro drift
Maximum angular velocity
Bandwidth
Power/consumption
Data I/O format
Zero point stability
1. After calibration, free magnetic field to tilt angles of ±20
RMS to ±45
Table A-5
Environmental Data
Operating temperature
Storage temperature
Maximum shock (performance)
EMI/RFI

Specifications

±3.0° peak; ±1.0° typical
±0.25°
±0.1° (gyro ±0.01)
±45°
0°/minute (auto-corrected)
45°/second
10 Hz
12-32 VDC/330 mA (stand-alone)
TracVision component: 11-16 VDC
3.5 amps nominal, 4.5 amps peak
RS-422 (NMEA 0183 Version 2.2)
±0.8°
°
tilt or roll.
-13°F to +130°F (-25°C to +55°C)
-40°F to +185°F (-40°C to +85°C)
20G, 11 msec
IEC 945; FCC Part 15J, Class B
1
°
; accuracy ±5.0
54-0161