Aeration Sleeve Details - Rinnai RF800 Operation & Installation Manual

Rf800 decorative gas log effect appliance
Table of Contents

Advertisement

4.
Low Pressure Setting: Turn 'OFF' the power
to the POV by separating the connector of the
two yellow wires that power the POV. The POV
will automatically default to 'Low Pressure'
operation. Keep the high pressure adjusting
nut stationary using a 10 mm spanner. Use an
appropriate screwdriver for setting screw B.
Turning clockwise increases the outlet pressure
whilst turning anticlockwise decreases the outlet
pressure.
Replace the dust cap C after pressure
5.
adjustments.
6.
Reconnect the POV Yellow wires power
connection.
To ensure the correct operation of the
modulating valve (POV) it is necessary
that the dust Cap C is returned to its
WARNING
original location.
7.
After re-checking the pressures, turn the
appliance 'OFF', remove manometer and replace
the ATPP screw D. Check all connections and
test points for leaks using soapy water solutions.
8.
Turn the appliance 'ON' and 'OFF' a few times
to confirm correct ignition and operation.
9.
During the initial burn in period, some smoke
and smell may be emitted. The appliance should
be run with both the flame and fan set to high in
a well ventilated room until these dissipate.
10. Check the flame pattern, see Abnormal Flame
Pattern", "When to call for Service" on page
7.
11. Proceed to the section "Trim Installation" on
page 20

AERATION SLEEVE DETAILS

It is important that the correct aeration sleeves are used for each gas type and burner media. The appliance should
have been supplied with the correct aeration sleeves. If the appliance is to be set up on propane with pebbles or
crystals then the sleeves supplied with the burner media need to be fitted. Refer to the notes supplied with the
burner media and the chart below for more information.
Gas Type
Natural Gas
Propane
Rinnai
C
PACK ASSEMBLY
Aeration
Sleeves
Burner Media
All
Logs/Coals
Pebbles or Crystals
19
INLET
TEST POINT
CAP
GAS CONTROL
AND IGNITION
HIGH PRESSURE
A
ADJUSTING NUT
LOW PRESSURE
B
ADJUSTING SCREW
B
FLAME UP BUTTON
FAN UP BUTTON
OFF TIMER BUTTON
Identification
groove
No. of ID Grooves on Sleeve (Depth of Sleeve)
No Sleeves
APPLIANCE OUTLET
D
TEST POINT PRESSURE
GAS
OUTLET
A
ON/OFF BUTTON
FLAME DOWN BUTTON
FAN DOWN BUTTON
None
1
RF800 OIM

Advertisement

Table of Contents
loading

Table of Contents