MASONRY CAVITY DESIGN

Remember that both gas and electricity are required within the cavity before the appliance is
installed (see, "Gas & Electrical Supplies" on page 12).
NOTE
These instructions are for either new masonry/non combustible cavities or existing masonry fire
places.
A flexi flue and adaptor is available for installations where access is restricted.
If the cavity can be completed after the engine and flue are installed then the adaptor might not
be required.
The flue adaptor can also be used with rigid flue where space allows.
The flue should be self supporting before the engine is installed.
This appliance is not designed for installation without a dedicated flue liner.
This appliance consists of a firebox and removable insulating panels. For masonry installations only, these panels
can be removed if cavity space is restricted. Remove as few or as many panels as required. The more panels
retained, the more efficient the appliance will be.
Take care not to damage the power cord when removing the back panel!
IMPORTANT
Rinnai
370
MIN
FLEXI FLUE
AND ADAPTOR
16
200 SINGLE SKIN
FLEXI FLUE LINER
229
RF800 OIM