Function control block (RCP-1530)
1 Filter control block
a ND filter selection buttons
These buttons are lit when the RCP has the filter servo control
permission. When they are not lit, the camera side has the
control permission. Pressing either the top or bottom button
once switches the control permission to the RCP. If there is no
filter servo or the camera does not have a filter, these buttons
do not light and the control permission can also not be
switched.
The v button changes the ND filters in order in the forward
direction. The V button changes them in the opposite
direction. Pressing and holding one of the buttons changes the
ND filters continuously.
b Standard value indicators
These light when standard values are set in the Standard Ind
menu. The indicators light in green when values are in their
standard state, and in amber when values are not in their
standard state.
c CC (color temperature conversion) filter selection
buttons
These buttons are lit when the RCP has the filter servo control
permission. When they are not lit, the camera side has the
control permission. Pressing either the top or bottom button
once switches the control permission to the RCP. If there is no
filter servo or the camera does not have a filter, these buttons
do not light and the control permission can also not be
switched.
The v button changes the CC filters in order in the forward
direction. The V button changes them in the opposite
direction. Pressing and holding one of the buttons changes the
ND filters continuously.
d ND filter display window
This window displays the ND filter that is currently selected.
e CC (color temperature conversion) filter display
window
This window displays the CC filter that is currently selected.
2 Master gain control block
a Standard value indicator
This lights when standard values are set in the Standard Ind
menu. The indicator lights in green when values are in their
standard state, and in amber when values are not in their
standard state.
b Master gain display window
This window displays the master gain that is currently set.
c Master gain selection buttons
This block is for setting the sensitivity of the camera. Each
press of the v (up) button increases the sensitivity, and each
press of the V (down) button decreases it. Pressing and
holding one of the buttons changes the sensitivity
continuously. The setting value (unit: dB) is displayed in the
displayed in the display window.