Installing The Remcs Function; Connection Configurations Supported By The Remcs Function - Fujitsu PRIMEQUEST 1000 Series Installation Manual

Remcs
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series REMCS Installation Manual
CHAPTER 1 REMCS Service Overview
Problem notification
When a hardware problem occurs in a server, automatically notifies the REMCS Center of the problem and sends
problem information including logs to the REMCS Center.
Whenever an event involving a hardware problem occurs in the same unit after the REMCS Center has been notified
of the hardware problem, notification thereon to the REMCS Center is suppressed. Events detected by PSA or SVS
are cleared when the operating system is rebooted or when PSA or SVS is stopped or restarted. When a problem
with a notification level that is higher than that of an event for which notification is being suppressed occurs in the
same part, problem notification takes place even within the notification suppression period. At this time, the
notification suppression time is cleared to 0, and the notification suppression continues. In the case of SVS, there
is no processing related to notification suppression time such as that for PSA. Accordingly, until a problem with a
high notification level occurs or until the events are cleared, notification of abnormalities is suppressed.
Periodic connection
Automatically connects to the REMCS Center at specified times to confirm the existence of the communication
path and REMCS Agent.
1.2.2

Installing the REMCS function

The REMCS function of the PRIMEQUEST 1000 series consists of the MMB and PSA (on the PRIMEQUEST
1800E) or SVS (on the PRIMEQUEST 1800E2) installed on the partition side.
Installation in the MMB
The MMB REMCS function is installed as standard. The function does not need to be installed.
Installation in PSA (on the PRIMEQUEST 1800E) or SVS (on the PRIMEQUEST 1800E2)
For details on the procedure for installing the function in PSA (on the PRIMEQUEST 1800E) or SVS (on the
PRIMEQUEST 1800E2), see Chapter 5 Work after Operating System Installation (PRIMEQUEST 1800E) or
Chapter 6 Work after Operating System Installation (PRIMEQUEST 1800E2) in the PRIMEQUEST 1000 Series
Installation Manual (C122-E107EN).
1.2.3

Connection configurations supported by the REMCS function

The PRIMEQUEST 1000 series supports only the connection configurations shown below. Each of these connection
configurations uses only SMTP for communication with the REMCS Center.
- Internet connection (e-mail)
With this connection configuration, communication with the REMCS Center is executed via the Internet.
- P-P connection (ISDN: e-mail)
With this connection configuration, communication with the REMCS Center is executed with a P-P system
using a line such an ISDN line.
4
C122-E120-06EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primequest 1800e2Primequest 1800e