3.2 Machine Parameter Adjustment

3.2.1 Setting the Machine Parameters

These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power is lost.
1. From standby, press <Menu>, <*>,<0>,<0>.
Set Parameters
2. Press <Enter>.
3. Call up the desired switch by pressing < > or< >, or by pressing the numeric keypad.
Select Parameters
000:00000000
4. Press <Enter>.
001:01010000
01010000
Bit No.
76543210
5. To navigate through the machine parameter settings:
• The bits are ranged from 7 (left) to 0 (right).
• Press <
> or <
• Press <0> or <1> on the numeric keypad, or < > or < >, to change the bit value.
• Press <Enter> to save the setting of the displayed parameter and return to the machine
parameter edit screen.
• Press <Menu> not to save the setting of the displayed parameter.
6. If you want to set other machine parameters, repeat step 3–5. Otherwise, proceed to step 7.
7. Press <Reset> to return the machine to standby.
Note: You can confirm the initial setting of each Machine parameter by the Machine Parameters List.
The Machine Parameters List will be printed by pressing <Menu>,<*>,<1>,<0>.

3.2.2 Clearing the Machine Parameters

Resets the machine parameters to factory defaults.
1. From standby, press <Menu>, <*>,<0>,<0>,< >.
Clear Parameters
2. Press <Enter>.
Clear Parameters
Yes → Enter
3. Press <Enter>. The machine parameters will reset to factory defaults.
Note: To finish the operation without clearing the parameters, press <Cancel>.
4. Press <Reset> to return the machine to standby.