Grounding Instructions - Windsor D250(115V) 10070100 Operating Instructions Manual

Table of Contents

Advertisement

GROUNDING INSTRUCTIONS

THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
ELECTRICAL:
The amp, hertz, and voltage are listed on the data
label found on each machine. Using voltages above
or below those indicated on the data label will cause
serious damage to the motors.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should
malfunction or break down, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor and
grounding plug. The plug must be inserted into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
The D250 is for use on a nominal 115-volt circuit, and
has a grounded plug that looks like the plug in "Fig. A".
A temporary adaptor that looks like the adaptor in "Fig
. C" may be used to connect this plug to a 2-pole
receptacle as shown in "Fig. B", if a properly grounded
outlet is not available. The temporary adaptor should
be used only until a properly grounded outlet (Fig. A)
can be installed by a qualified electrician. The green
colored rigid ear, lug, or the like extending from the
adaptor must be connected to a permanent ground
such as a properly grounded outlet box cover.
Whenever the adaptor is used, it must be held in place
by a metal screw.
The D250IE is for use on a nominal 230-volt circuit.
of electric shock. Check with a qualified electrician or
service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug
provided with the appliance - if it will not fit the outlet,
have a proper outlet installed by a qualified electrician.
3
Improper connection of the
equipment-grounding
conductor can result in a risk
D-250 86038570 05/11/07
PROPER GROUNDING (115V)
Grounding Pin
Grounded
Outlet
Fig. A
Tab For Grounding Screw
Adaptor
NOTE: In Canada, the use of a temporary adaptor is not
permitted by the Canadian Electrical Code
CHEMICALS
Suitable Chemicals
Alkalis
Detergents
Hydroxides
Soaps
Vinegar
Warning:
Using the incompatible chemicals listed above will
damage the machine. Damages of this type are
not covered under the 6-3-1 warranty. Carefully
read ingredients on manufacturer's label before
using any product in this machine.
Metal Screw
Adaptor
Grounded Outlet Box
Fig. B
Fig. C
Non-Compatible
Aldehydes
Aromatics Hydrocarbons
SP Butyls
Carbon Tetrachloride
Clorox*
Chlorinated Bleaches
Chlorinated Hydrocarbons
Lysol*
Methyl Ethel Ketone (MEK)
Perchorethylene (perc)
Phenolics
Trichlorethylene
D-Limonene

Advertisement

Table of Contents
loading

This manual is also suitable for:

D250

Table of Contents