Message
Enter AppLockEnumWindows
Enter DecryptPwd
Enter EncryptPwd
Enter FullScreenMode
Enter GetAppInfo
Enter password dialog
Enter password timeout
Enter restart app timer
Enter TaskbarScreenMode
Enter ToAdmin
Enter ToUser
Enter verify password
Exit AppLockEnumWindows-Found
Exit AppLockEnumWindows-Not found
Exit DecryptPwd
Exit EncryptPwd
Exit FullScreenMode
Exit GetAppInfo
Exit password dialog
Exit password dialog-cancel
Exit password dialog-OK
Exit password timeout
Exit restart app timer
Exit TaskbarScreenMode
Explanation and/or corrective action
In order for AppLock to control the application being
locked so it can prevent the application from exiting,
AppLock launches the application and has to wait
until it has created and initialized its main window.
This message is logged when the function that waits
for the application initialization is entered.
Entering the password decryption process.
Entering the password encryption processing.
Entering the function that switches the screen
mode. In full screen mode, the taskbar is hidden
and disabled.
Processing is at the beginning of the function that
retrieves the application information from the
registry.
Entering the password dialog processing.
Entering the password timeout processing.
Some application shut down before AppLock can
stop it. In these cases, AppLock gets notification of
the exit. When the notification is received, AppLock
starts a timer to restart the application. This
message logs that the timer has expired and the
processing is at the beginning of the timer function.
Entering the function that switches the screen to
non-full screen mode and enable the taskbar.
Entering the function that handles a mode switch
into admin mode.
Entering the function that handles the mode switch
to user mode
Entering the password verification processing.
There are two exit paths from the enumeration
function. This message denotes the enumeration
function found the application.
There are two exit paths from the enumeration
function. This message denotes the enumeration
function did not find the application.
Exiting password decryption processing.
Exiting password encryption processing.
Exiting the function that switches the screen to full
screen.
Processing is at the end of the function that
retrieved the application information from the
registry.
Exiting password prompt processing.
Exiting password prompt w/cancel.
Exiting password prompt successfully.
Exiting password timeout processing.
Processing is at the end of the timer function
Exiting the function that switches the screen mode
back to normal operation for the administrator.
Level
LOG_EX
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
6 - 15