Test Mode 4 (Binary Signal Generation) - Panasonic DF-1100 Service Manual

Hide thumbs Also See for DF-1100:
Table of Contents

Advertisement

5.5

Test Mode 4 (Binary Signal Generation)

This test mode is used to check the binary signal output. Signals can be output to the line using the following
procedure.
Step
FAX
1
Make sure that the FAX lamp is on.
If not, press FAX to set the " FAX Mode ".
2
Press " FUNCTION " and then " 7 ".
3
Press " MONITOR " four times, then press " * ".
4
Press " 4 " and " START ".
5
Enter the signal number (1-9) to select the binary signal.
Press " STOP " to end the signal generation. To select
6
another signal, repeat step 4.
7
Press " STOP " to return to standby.
Operation or Unit Condition
Number
1
V21 300 bps
2
V33 14400 bps
3
V33 12000 bps
4
V17 TC9600 bps
5
V17 TC7200 bps
6
V29 9600 bps
7
V29 7200 bps
8
V27ter 4800 bps
9
V27ter 2400 bps
Binary Signal Table
12-JUN-1998 15:00
SET MODE
ENTER NO. OR
TEST MODE
NO.=_
SIGNAL TEST
IDLE (ENTER 1–9)
SIGNAL TEST
V21 300bps
TEST MODE
NO.=_
12-JUN–1998 15:00
Signals
Test Modes
LCD Display
00%
(1-6)
(ENTER 0-13)
(ENTER 0-13)
00%