Duct Connected-Low/Middle Static Pressure Type (Fdum) - Mitsubishi Heavy Industries FDT Series Technical Manual

Hyper inverter packaged air-conditioners fdt, fdf, fdtc, fden, srk, fdc, fdum series
Hide thumbs Also See for FDT Series:
Table of Contents

Advertisement

(5) Duct connected-Low / Middle static pressure type (FDUM)
(a) Singl type
Model
Item
Power source
Operation data
Nominal capacity
kW
Power consumption
kW
Running current
Power factor
%
Inrush current
Sound Pressure Level
dB(A)
Exterior dimensions
mm
Height × Width × Depth
Exterior appearance
(Munsell color)
Net weight
kg
Refrigerant equipment
Compressor type & Q'ty
Starting method
Refrigerant oil
Heat exchanger
Refrigerant control
Air handling equipment
Fan type & Q'ty
Motor <Starting method>
W
Air flow (Standard)
CMM
External static pressure
Pa
Outdoor air intake
Air filter, Q'ty
Shock & vibration absorber
Insulation (noise & heat)
Electric heater
W
Remote controller
Room temperature control
Safety equipment
Installation data
mm
Refrigerant piping size
Connecting method
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Refrigerant Quantity
Drain pump
Drain
Insulation for piping
IP code
Standard Accessories
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Operation
Cooling
27˚C
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound pressure level indicates the value in an anechoic chamber. During operation these value are somewhat higher due to
ambient temperature.
(4) The operation data indicates when the air-conditioner is operated at 230V50Hz or 220V60Hz.
(5) Static pressure of optional air filter "UM-FL1EF" is 5Pa initially.
(6) If wireless remote controller is used, only 3-speed fan setting (Hi-Me-Lo) is available.
Indoor unit FDUM50VF
Cooling
5.0 [ 2.2 (Min.)~5.6 (Max.)]
1.38
A
6.3 / 6.6
A
P-Hi : 37 Hi : 32 Me : 29 Lo : 26
280 × 750 × 635
Louver fin & inner grooved tubing
Centrifugal fan × 1
100 < Direct line start >
P-Hi : 13 Hi : 10 Me : 9 Lo : 8
Standard : 35 Max : 100
Possible
Procure locally
Rubber sleeve (for fan motor)
Polyurethane form
Thermostat by electronics
Overload protection for fan motor
Frost protection thermostat
Liquid line : I/U
Gas line
Flare piping
Max.20m (Outdoor unit is higher)
Max.20m (Outdoor unit is lower)
R410A 1.5kg in outdoor unit (incl. the amount for the piping of : 15m)
Built-in Drain pump
Hose Connectable with VP20
IPXO
Drain hose
Outdoor air temperature
DB
WB
DB
19˚C
35˚C
20˚C
7˚C
FDUM50ZJXVF
95
5 < Max.running current 15 >
29
wired : RC-E5 (option) wireless : RCN-KIT3-E (option)
6.35 (1/4") Pipe
6.35 (1/4") × 0.8 O/U
:
12.7 (1/2") Pipe
12.7 (1/2") × 0.8
Max.30m
Necessary (both Liquid & Gas lines)
External static pressure of indoor unit
WB
24˚C
6˚C
-
61
-
'12 • PAC-T-173
Adapted to RoHS directive
Outdoor unit SRC50ZJX-S
220-240V~50Hz / 220V~60Hz
Heating
5.4 [ 0.6 (Min.)~6.3 (Max.)]
1.45
6.6 / 6.9
96
Cooling : 54 Heating : 50
640 × 800 (+71) × 290
Stucco White
(4.2Y7.5/1.1) near equivalent
45
RMT5113MCE2 (Twin Rotary type) × 1
Direct line start
0.45 MA68
M shape fin & inner grooved tubing
Capillary tubes + Electronic expansion valve
Propeller fan × 1
34 < Direct line start >
Cooling : 40 Heating : 33
0
Rubber sleeve (for Compressor)
Internal thermostat for fan motor
Abnormal discharge temperature protection.
6.35 (1/4")
12.7 (1/2")
Flare piping
See page 152
Holes size
20 × 5pcs
IPX4
Drain elbow, Drain hole grommet
Pa
35
PJG000Z032