FDT60ZJXVF
Model
Indoor unit
Cool Mode
Outdoor
18 °C DB
21 °C DB
air temp.
12 °C WB
14 °C WB
°C DB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
5.22 5.12 5.44 5.02 5.71 5.50 5.88 5.42 6.07 5.33 6.45 5.69 6.84 5.50
27
5.27 5.16 5.50 5.03 5.78 5.52 5.94 5.43 6.11 5.34 6.44 5.69
29
5.18 5.08 5.41 5.01 5.69 5.50 5.86 5.42 6.02 5.33 6.36 5.68
31
5.09 4.99 5.32 4.99 5.60 5.48 5.77 5.40 5.94 5.31 6.27 5.67
33
4.53 4.44 4.82 4.72 5.23 4.96 5.52 5.41 5.69 5.38 5.85 5.30 6.19 5.66
35
4.60 4.51 4.81 4.71 5.15 4.94 5.43 5.32 5.60 5.36 5.77 5.28 6.10 5.64
37
4.52 4.43 4.73 4.64 5.06 4.92 5.35 5.24 5.51 5.35 5.68 5.27 6.01 5.63
39
4.44 4.35 4.65 4.56 4.98 4.88 5.26 5.15 5.43 5.32 5.59 5.25 5.92 5.62
41
4.37 4.28 4.58 4.49 4.90 4.80 5.18 5.08 5.34 5.23 5.51 5.24 5.83 5.61
43
4.29 4.20 4.50 4.41 4.82 4.72 5.10 5.00 5.26 5.15 5.42 5.22 5.74 5.60
FDT71VNXVF
Model
Indoor unit
Cool Mode
Outdoor
18 °C DB
21 °C DB
air temp.
12 °C WB
14 °C WB
°C DB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
6.46 6.22 6.89 6.01 7.32 6.55 7.54 6.49 7.78 6.42 8.26 6.82 8.74 6.66
27
6.45 6.21 6.87 6.01 7.30 6.55 7.52 6.48 7.74 6.41 8.18 6.80
29
6.34 6.17 6.75 5.96 7.19 6.51 7.41 6.45 7.64 6.38 8.09 6.77
31
6.23 6.11 6.64 5.93 7.08 6.48 7.31 6.42 7.54 6.35 7.99 6.75
33
5.77 5.62 6.05 5.93 6.53 5.89 6.97 6.44 7.20 6.38 7.44 6.32 7.90 6.73
35
5.67 5.56 5.95 5.83 6.42 5.85 6.86 6.41 7.10 6.35 7.34 6.29 7.81 6.70
37
5.58 5.47 5.85 5.73 6.31 5.81 6.72 6.36 6.95 6.31 7.18 6.25 7.64 6.66
39
5.49 5.38 5.76 5.64 6.20 5.77 6.59 6.32 6.81 6.27 7.03 6.21 7.46 6.62
41
5.39 5.28 5.67 5.56 6.09 5.73 6.45 6.28 6.66 6.22 6.87 6.16 7.29 6.57
43
5.30 5.19 5.57 5.46 5.97 5.69 6.31 6.18 6.51 6.18 6.71 6.12 7.12 6.53
Note(1) These data show average statuses.
Note(1)
Depending on the system control, there may be ranges where the operation is not conducted continuously.
Note(1)
These data show the case where the operation frequency of a compressor is fixed.
(2) Capacities are based on the following conditions.
(2)
Corresponding refrigerant piping length :7.5m
(2)
Level difference of Zero.
(3) Symbols are as follows.
TC : Total cooling capacity
SHC : Sensible heat capacity
FDT60VF
Outdoor unit
Indoor air temperature
23 °C DB
26 °C DB
27 °C DB
16 °C WB
18 °C WB
19 °C WB
TC
SHC
TC
SHC
TC
4.73 4.64 4.98 4.88 5.11 5.01 5.25 5.15 5.53 5.42 5.81 5.39
4.84 4.74 5.11 5.01 5.24 5.14 5.39 5.22 5.67 5.56 5.96 5.40
4.95 4.85 5.24 5.14 5.38 5.27 5.52 5.24 5.82 5.61 6.11 5.42
5.07 4.92 5.37 5.26 5.51 5.35 5.66 5.26 5.96 5.63 6.25 5.43
5.17 4.95 5.48 5.37 5.63 5.37 5.81 5.29 6.17 5.65 6.54 5.47
5.33 4.99 5.59 5.48 5.74 5.39 5.96 5.31 6.39 5.69 6.82 5.50
5.39 5.01 5.65 5.49 5.81 5.41 6.01 5.32 6.42 5.69 6.83 5.50
FDT71VF
Outdoor unit
Indoor air temperature
23 °C DB
26 °C DB
27 °C DB
16 °C WB
18 °C WB
19 °C WB
TC
SHC TC
SHC TC
4.87 4.77 6.02 5.90 6.59 6.20 6.79 6.14 7.19 6.55 7.59 6.40
5.33 5.22 6.32 6.19 6.82 6.27 7.03 6.21 7.45 6.61 7.88 6.46
5.79 5.63 6.63 6.33 7.05 6.34 7.27 6.27 7.71 6.68 8.16 6.53
6.26 5.79 6.94 6.43 7.27 6.40 7.51 6.34 7.97 6.74 8.44 6.59
6.59 5.91 7.16 6.50 7.44 6.45 7.68 6.39 8.15 6.79 8.63 6.63
6.93 6.03 7.38 6.57 7.60 6.50 7.84 6.44 8.33 6.84 8.82 6.67
6.91 6.02 7.35 6.56 7.57 6.49 7.81 6.43 8.30 6.83 8.78 6.67
SRC60ZJX-S
28 °C DB
31 °C DB
20 °C WB
22 °C WB
SHC
TC
SHC
TC
SHC
FDC71VNX
28 °C DB
31 °C DB
20 °C WB
22 °C WB
SHC TC
SHC TC
SHC TC
-
155
-
Heat Mode
Indoor air temperature
Outdoor
33 °C DB
air temp.
°C DB °C WB
24 °C WB
16
TC
SHC
-19.8 -20
-17.7 -18
-15.7 -16
-13.5 -14
3.97 3.91 3.85 3.79 3.73
-11.5 -12
4.22 4.16 4.10 4.04 3.98
-9.5
-10
4.47 4.41 4.35 4.29 4.23
-7.5
-8
4.72 4.66 4.60 4.54 4.48
-5.5
-6
4.81 4.76 4.70 4.65 4.60
-3.0
-4
4.90 4.86 4.81 4.77 4.72
-1.0
-2
5.00 4.96 4.92 4.88 4.84
1.0
0
5.09 5.06 5.03 4.99 4.96
2.0
1
5.14 5.11 5.08 5.05 5.02
3.0
2
5.47 5.44 5.41 5.37 5.34
5.0
4
6.12 6.09 6.05 6.01 5.98
7.0
6
6.78 6.74 6.70 6.66 6.61
9.0
8
7.12 7.08 7.03 6.98 6.94
11.5
10
7.47 7.41 7.36 7.31 7.26
13.5
12
7.89 7.82 7.76 7.65 7.59
15.5
14
8.31 8.23 8.15 7.99 7.93
16.5
16
8.53 8.44 8.35 8.16 8.09
Heat Mode
(kW)
Indoor air temperature
Outdoor
33 °C DB
air temp.
°C DB °C WB 16
24 °C WB
-19.8 -20
SHC
3.95 3.93 3.91 3.88 3.86
-17.7 -18
4.18 4.16 4.14 4.11 4.09
-15.7 -16
4.42 4.39 4.37 4.34 4.32
-13.5 -14
4.68 4.65 4.63 4.60 4.57
-11.5 -12
4.94 4.91 4.88 4.85 4.82
-9.5
-10
5.20 5.17 5.14 5.11 5.08
-7.5
-8
5.46 5.43 5.40 5.36 5.33
-5.5
-6
5.59 5.55 5.52 5.48 5.44
-3.0
-4
5.71 5.68 5.64 5.60 5.56
-1.0
-2
5.84 5.80 5.76 5.72 5.67
1.0
0
5.97 5.92 5.88 5.83 5.79
2.0
1
6.03 5.98 5.94 5.89 5.85
3.0
2
6.45 6.40 6.35 6.30 6.25
5.0
4
7.29 7.23 7.18 7.12 7.06
7.0
6
8.13 8.06 8.00 7.93 7.87
9.0
8
8.42 8.36 8.29 8.23 8.16
11.5
10
8.72 8.65 8.59 8.52 8.46
13.5
12
9.20 9.13 9.06 9.00 8.92
15.5
14
9.69 9.61 9.53 9.47 9.39
16.5
16
9.93 9.85 9.77 9.71 9.62
'12 • PAC-T-173
°C DB
18
20
22
24
PJF000Z220
(kW)
°C DB