(3) Duct connected-Low / Middle static pressure tpye (FDUM)
Item
Power source
Nominal cooling capacity (range)
Nominal heating capacity (range)
Power consumption
Max power consumption
Running current
Inrush current, max current
Operation
data
Power factor
EER
COP
Sound power level
Sound pressure level
Silent mode sound pressure level
Exterior dimensions (Height x Width x Depth)
Exterior appearance
( Munsell color )
Net weight
Compressor type & Q'ty
Compressor motor (Starting method)
Refrigerant oil (Amount, type)
Refrigerant (Type, amount, pre-charge length)
Heat exchanger
Refrigerant control
Fan type & Q'ty
Fan motor (Starting method)
Air flow
Available external static pressure
Outside air intake
Air filter, Quality / Quantity
Shock & vibration absorber
Electric heater
Remote control
Operation
Room temperature control
control
Operation display
Safety equipments
Refrigerant piping size ( O.D. )
Connecting method
Attached length of piping
Installation
data
Insulation for piping
Refrigerant line (one way) length
Vertical height diff. between O.U. and I.U.
Drain hose
Drain pump, max lift height
Recommended breaker size
L.R.A. (Locked rotor ampere)
Interconnecting wires
Size x Core number
IP number
Standard accessories
Option parts
Notes (1) The data are measured at the following conditions.
Indoor air temperature
Item
Operation
DB
Cooling
27˚C
Heating
20˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat
higher due to ambient conditions.
(4) Select the breaker size according to the own national standard.
(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.
(6) Static pressure of optional air filter "UM-FL1EF" is 5Pa initially.
(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3 and RC-E5 only)
Model
Indoor unit FDUM40VF
kW
kW
Cooling
Heating
kW
Cooling
Heating
A
Cooling
%
Heating
Cooling
Heating
Cooling
Heating
dB(A)
Cooling
P-Hi : 37 Hi : 32 Me : 29 Lo : 26
Heating
mm
280 × 750 × 635
kg
kW
kg
R410A 1.5kg in outdoor unit (incl. the amount for the piping of : 15m)
Louver fin & inner grooved tubing
Centrifugal fan ×1
W
100 < Direct line start >
Cooling
3
m
/min
P-Hi : 13 Hi : 10 Me : 9 Lo : 8
Heating
Pa
Standard : 35 Max : 100
Rubber sleeve(for fan motor)
W
(option) wired : RC-EX3 , RC-E5 , RCH-E3 wireless : RCN-KIT4-E2
Liquid line: I.U.φ6.35 (1/4") Pipeφ6.35(1/4")x0.8 O.U.φ6.35 (1/4")
mm
m
m
m
Max.20m (Outdoor unit is higher)
Hose Connectable with VP25(O.D.32)
mm
Built-in drain pump , 600
A
A
1.5mm
Mounting kit, Drain hose
Outdoor air temperature
WB
DB
19˚C
35˚C
7˚C
-
FDUM40ZSXVF
1 Phase 220-240V 50Hz / 220V 60Hz
4.0 [ 1.1(Min.)- 4.7(Max.)]
4.5 [ 0.6(Min.)- 5.4(Max.)]
0.952
1.07
2.60
4.4 / 4.6
4.9 / 5.1
5 , 12
94
95
4.20
4.21
60
29
Capillary tubes + Electronic expansion valve
Possible
Procure locally
Thermostat by electronics
Overload protection for fan motor.
Frost protection thermostat.
Internal thermostat for fan motor.
Abnormal discharge temperature protection.
φ12.7 (1/2")
φ12.7 (1/2")x0.8
Gas line:
Flare piping
Necessary (both Liquid & Gas lines)
Max.30m
4.8
2
x 4 cores (Including earth cable) / Termainal block (Screw fixing type)
IPX0
UM-FL1EF
External static pressure
of indoor unit
WB
24˚C
35Pa
6˚C
11
-
'17 • PAC-T-256
Outdoor unit SRC40ZSX-S
63
50
49
Cooling : 42 / Heating : 43
640×800(+71)×290
Stucco white
( 4.2Y7.5/1.1 ) near equivalent
45
RMT5113MCE2 ( Twin rotary type )×1
Direct line start
0.45 ( MA68 )
M shape fin & inner grooved tubing
Propeller fan ×1
34 < Direct line start >
36
33
Rubber sleeve(for compressor )
φ12.7 (1/2")
Flare piping
Max.20m (Outdoor unit is lower)
Holes size φ20 x 5pcs
IPX4
Drain elbow, Drain hole grommet
The pipe length is 7.5m.
Standards
ISO5151-T1
PJG000Z159