Mitsubishi Heavy Industries FDT Series Technical Manual page 167

Hyper inverter packaged air-conditioners fdt, fdf, fdtc, fden, srk, fdc, fdum series
Hide thumbs Also See for FDT Series:
Table of Contents

Advertisement

FDTC100VNXPVF
Model
Cool Mode
Outdoor
18 °C DB
21 °C DB
air temp.
12 °C WB
14 °C WB
°C DB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
8.95 7.26 9.64 7.16 10.30 7.67 10.62 7.63 10.97 7.59 11.66 7.96 12.36 7.83
27
8.91 7.24 9.64 7.16 10.33 7.69 10.64 7.64 10.96 7.59 11.59 7.93
29
8.84 7.20 9.51 7.10 10.16 7.61 10.48 7.57 10.80 7.52 11.45 7.88
31
8.76 7.16 9.37 7.04 10.00 7.54 10.32 7.51 10.65 7.46 11.30 7.82
33
8.21 6.72 8.58 7.08 9.23 6.97 9.83 7.47 10.16 7.44 10.49 7.40 11.15 7.77
35
7.77 6.49 8.31 6.95 9.09 6.91 9.66 7.40 10.00 7.37 10.34 7.34 11.01 7.72
37
7.68 6.44 8.18 6.88 8.92 6.83 9.49 7.33 9.81 7.30 10.13 7.26 10.77 7.63
39
7.58 6.39 8.04 6.82 8.76 6.76 9.31 7.25 9.62 7.22 9.93 7.18 10.54 7.55
41
7.49 6.35 7.91 6.75 8.59 6.68 9.14 7.18 9.43 7.14 9.73 7.10 10.31 7.47
43
7.40 6.30 7.78 6.69 8.42 6.61 8.96 7.11 9.24 7.07 9.52 7.02 10.08 7.38
Model
FDTC100VSXPVF
Cool Mode
Outdoor
18 °C DB
21 °C DB
air temp.
12 °C WB
14 °C WB
°C DB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
8.95 7.26 9.64 7.16 10.30 7.67 10.62 7.63 10.97 7.59 11.66 7.96 12.36 7.83
27
8.91 7.24 9.64 7.16 10.33 7.69 10.64 7.64 10.96 7.59 11.59 7.93
29
8.84 7.20 9.51 7.10 10.16 7.61 10.48 7.57 10.80 7.52 11.45 7.88
31
8.76 7.16 9.37 7.04 10.00 7.54 10.32 7.51 10.65 7.46 11.30 7.82
33
8.21 6.72 8.58 7.08 9.23 6.97 9.83 7.47 10.16 7.44 10.49 7.40 11.15 7.77
35
7.77 6.49 8.31 6.95 9.09 6.91 9.66 7.40 10.00 7.37 10.34 7.34 11.01 7.72
37
7.68 6.44 8.18 6.88 8.92 6.83 9.49 7.33 9.81 7.30 10.13 7.26 10.77 7.63
39
7.58 6.39 8.04 6.82 8.76 6.76 9.31 7.25 9.62 7.22 9.93 7.18 10.54 7.55
41
7.49 6.35 7.91 6.75 8.59 6.68 9.14 7.18 9.43 7.14 9.73 7.10 10.31 7.47
43
7.40 6.30 7.78 6.69 8.42 6.61 8.96 7.11 9.24 7.07 9.52 7.02 10.08 7.38
Note(1) These data show average statuses.
Note(1)
Depending on the system control, there may be ranges where the operation is not conducted continuously.
Note(1)
These data show the case where the operation frequency of a compressor is fixed.
(2) Capacities are based on the following conditions.
(2)
Corresponding refrigerant piping length :7.5m
(2)
Level difference of Zero.
(3) Symbols are as follows.
TC : Total cooling capacity
SHC : Sensible heat capacity
Indoor unit
FDTC50VF (2 units)
Indoor air temperature
23 °C DB
26 °C DB
27 °C DB
16 °C WB
18 °C WB
19 °C WB
TC
SHC TC
SHC TC
8.33 6.57 8.84 7.06 9.10 7.01 9.38 6.97 9.94 7.33 10.50 7.22
8.63 6.70 9.17 7.19 9.43 7.14 9.73 7.10 10.32 7.47 10.92 7.35
8.93 6.84 9.49 7.33 9.77 7.28 10.09 7.24 10.71 7.61 11.34 7.49
9.23 6.97 9.82 7.47 10.11 7.42 10.44 7.38 11.10 7.75 11.75 7.63
9.44 7.07 10.04 7.56 10.34 7.51 10.68 7.48 11.35 7.84 12.01 7.71
9.64 7.16 10.26 7.66 10.57 7.61 10.91 7.57 11.59 7.93 12.28 7.81
9.64 7.16 10.28 7.66 10.59 7.62 10.94 7.58 11.63 7.95 12.32 7.82
Indoor unit
FDTC50VF (2 units)
Indoor air temperature
23 °C DB
26 °C DB
27 °C DB
16 °C WB
18 °C WB
19 °C WB
TC
SHC TC
SHC TC
8.33 6.57 8.84 7.06 9.10 7.01 9.38 6.97 9.94 7.33 10.50 7.22
8.63 6.70 9.17 7.19 9.43 7.14 9.73 7.10 10.32 7.47 10.92 7.35
8.93 6.84 9.49 7.33 9.77 7.28 10.09 7.24 10.71 7.61 11.34 7.49
9.23 6.97 9.82 7.47 10.11 7.42 10.44 7.38 11.10 7.75 11.75 7.63
9.44 7.07 10.04 7.56 10.34 7.51 10.68 7.48 11.35 7.84 12.01 7.71
9.64 7.16 10.26 7.66 10.57 7.61 10.91 7.57 11.59 7.93 12.28 7.81
9.64 7.16 10.28 7.66 10.59 7.62 10.94 7.58 11.63 7.95 12.32 7.82
Outdoor unit
FDC100VNX
28 °C DB
31 °C DB
20 °C WB
22 °C WB
SHC TC
SHC TC
SHC TC
Outdoor unit
FDC100VSX
28 °C DB
31 °C DB
20 °C WB
22 °C WB
SHC TC
SHC TC
SHC TC
-
166
-
(kW)
Heat Mode
Outdoor
Indoor air temperature
33 °C DB
air temp.
24 °C WB
°C DB °C WB 16
-19.8 -20
7.30 7.24 7.18 7.12 7.06
SHC
-17.7 -18
7.74 7.68 7.62 7.55 7.49
-15.7 -16
8.18 8.12 8.05 7.99 7.92
-13.5 -14
8.54 8.47 8.40 8.33 8.27
-11.5 -12
8.89 8.82 8.75 8.68 8.61
-9.5
-10
9.25 9.17 9.10 9.03 8.95
-7.5
-8
9.60 9.53 9.45 9.38 9.30
-5.5
-6
10.00 9.92 9.84 9.76 9.68
-3.0
-4
10.39 10.31 10.23 10.14 10.06
-1.0
-2
10.79 10.70 10.62 10.53 10.44
1.0
0
11.18 11.09 11.01 10.91 10.82
2.0
1
11.38 11.29 11.20 11.10 11.01
3.0
2
11.38 11.29 11.20 11.10 11.01
5.0
4
11.38 11.29 11.20 11.11 11.01
7.0
6
11.37 11.29 11.20 11.11 11.01
9.0
8
11.85 11.76 11.67 11.58 11.48
11.5
10
12.32 12.23 12.15 12.05 11.95
13.5
12
12.97 12.88 12.78 12.68 12.72
15.5
14
13.62 13.52 13.41 13.32 13.49
13.95 13.84 13.72 13.63 13.87
16.5
16
Heat Mode
(kW)
Indoor air temperature
Outdoor
33 °C DB
air temp.
24 °C WB
°C DB °C WB 16
-19.8 -20
11.29 11.20 11.11 11.02 10.93
SHC
-17.7 -18
11.34 11.25 11.16 11.06 10.97
-15.7 -16
11.38 11.29 11.20 11.11 11.02
-13.5 -14
11.38 11.29 11.20 11.11 11.02
-11.5 -12
11.38 11.29 11.20 11.11 11.02
-9.5
-10
11.38 11.29 11.20 11.11 11.02
-7.5
-8
11.37 11.29 11.20 11.11 11.02
-5.5
-6
11.38 11.29 11.20 11.11 11.02
-3.0
-4
11.38 11.29 11.20 11.11 11.01
-1.0
-2
11.38 11.29 11.20 11.11 11.01
1.0
0
11.38 11.29 11.20 11.10 11.01
2.0
1
11.38 11.29 11.20 11.10 11.01
3.0
2
11.38 11.29 11.20 11.10 11.01
5.0
4
11.38 11.29 11.20 11.11 11.01
7.0
6
11.37 11.29 11.20 11.11 11.01
9.0
8
11.85 11.76 11.67 11.58 11.48
11.5
10
12.32 12.23 12.15 12.05 11.95
13.5
12
12.97 12.88 12.78 12.68 12.72
15.5
14
13.62 13.52 13.41 13.32 13.49
16.5
16
13.95 13.84 13.72 13.63 13.87
'12 • PAC-T-173
(kW)
°C DB
18
20
22
24
A
PJA003Z382
(kW)
°C DB
18
20
22
24
A
PJA003Z382

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents