Oki C9850 Maintenance Manual page 184

Table of Contents

Advertisement

Display
Service Call
Thermistor indicates
172: Error
High Temperature
176: Error
(HOT) Error.
Service Call
Thermistor indicates
173: Error
Low Temperature
177: Error
(COLD) Error.
Service Call
Wrong Fuser Standard
179: Error
Service Call
The engine detects
180: Error
communication is
to
not possible with the
186: Error
optional unit.
180:Envelope Feeder
(Unused)
181:Duplex unit
182:Tray2 unit
183:Tray3 unit
184:Tray4 unit
185:Tray5 unit
186:Finisher unit
Service Call
Communication with
187: Error
control panel failed.
Service Call
Sub-CPU I/F Error
188: Error
Service Call
Inverter Unit I/F Error
189: Error
Service Call
System Memory
190: Error
Overlow
Service Call
PU Firm Download
200: Error
Error
to
202: Error
Power
Custom Media Table
On/off209:
Download Error
DOWNLOAD
ERROR
Service Call
CU Program
203: Error
Dysfunction
204: Error
207: Error
to
214: Error
Power Off/on
nnn: p
0xFOC: Error
0xFOD: Error
0xFFE: Error
0xFFF: Error
43627911TH Rev. 3
Table 7-1-1 Operator Alarm (5/10)
Cause
Error Description and Analysis
1) Is an Error message displayed?
2) Does the Error take place
again?
1) Is an Error message displayed?
2) Does the Error take place
again?
1) Is the model and power voltage
of the fuser mounted proper?
2) Fuser is properly mounted, but
Error results again.
1) Is an Error message displayed?
2) Does the Error take place
again?
Is the control panel and cable
connected properly?
Sub-CPU Communication Error
1) Inverter communications error
2) Does the Error take place
again?
System Memory Overlow
Error occurred when downloading
PU irmware.
Failed to download custom media
table.
Detected illegal process with CU
program.
Oki Data CONFIDENTIAL
Remedy
Judgement
Yes
Turn ON power again.
Yes
Leave in that state for 30
minutes then turn ON power
again.
Yes
Turn ON power again.
Yes
Leave in that state for 30
minutes then turn ON power
again.
No
Assemble the proper fuser.
Yes
Check to see that the fuser is
properly assemble.
Yes
Replace fuser.
Yes
Turn ON power again.
Yes
Replace optional unit.
No
Connect properly
Yes
Replace the control panel and
cable.
Check the connection of the
S2M board.
Replace the S2M board.
Yes
Check the connection of the I/F
cable.
Yes
Replace the V72-3 board.
Power OFF/ON
Replace CU PCB. (Replace
EEPROM)
After turning ON the power
again, try downloading again.
(This process isn't executed for
regular operations, therefore,
will not occur)
After turning ON the power
again, try downloading again.
(This process isn't executed for
regular operations, therefore,
will not occur)
Yes
Write down the 24 digit number
displayed on the LCD panel and
report it.
Turn OFF the power. Then
check the insertion of the CU
board. Now turn ON the power
again.
600 1200
184 /

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9650Mps9650c

Table of Contents