Display
Service Call
CU Slot2 DIMM
032: Error
RAM Check Error
Service Call
Slot1 RAM
036: Error
Spec error
Speciication of DIMM
in CU RAM slot is
unsupported.
Service Call
Slot2 RAM Spec error
037: Error
Speciication of DIMM
in CU RAM slot2 is
unsupported.
Service Call
CU EEPROM
040: Error
ERROR
Service Call
CU FLASH
041: Error
ERROR
CU PCB lash
ROM error
Service Call
CU PCB lash ROM
042: Error
error
to
Flash File System Error
045: Error
Service Call
PS+PCL Model CU
048: Error
ROM is mounted on a
PCL model unit.
Service Call
CU Type Mismatch
049: Error
CU ROM model
mismatches unit.
Service Call
Operator Panel Error
050: Error
Service Call
CU FAN ERROR
051: Error
CPU cooling fan of CU
PCB is abnormal.
Power Off/on
Image Processor Driver
052: Error
Error
Power Off/on
Parallel Interface Driver
060: Error
Error
Power Off/on
USB Drive Error
062: Error
Power Off/on
Network comm.
063: Error
Error H/W I/F
abnormality between
CU-NIC.
Power Off/on
CANT_HAPPEN
070: Error
PS Firmware
Abnormality
Detection
Power Off/on
Engine communication
072: Error
error
I/F Error between PU-
CU.
43627911TH Rev. 3
Table 7-1-1 Operator Alarm (2/10)
Cause
Error Description and Analysis
Is the applicable RAM DIMM
mounted properly?
Is operation restored by replacing
the applicable RAM DIMM?
Is this a standard RAM DIMM?
Is the applicable RAM DIMM
difference mounted normal?
Is operation restored by replacing
the applicable RAM DIMM?
Is this a standard RAM DIMM?
Is the applicable RAM DIMM
difference mounted normal?
Is operation restored by replacing
the applicable RAM DIMM?
Is the problem corrected by
replacing the CU PCB EEPROM?
Is the error display reproducible?
Failed to access lash memory that
is surface-mounted on CU PCB.
Is a standard model program ROM
mounted?
Is a standard model program ROM
mounted?
Is the error display reproducible?
Is the connection of the CU PCB
normal?
Replace and restore fan?
Is the error display reproducible?
Is the error display reproducible?
Is the error display reproducible?
Is the Network PCB properly
mounted?
Does replacement of the network
PCB correct the problem?
Check if problem is corrected by
turning OFF/ON Power/
Is the CU Assy properly mounted?
Does replacement of the CU
PCB correct the problem?
Oki Data CONFIDENTIAL
Remedy
Judgement
No
Re-mount applicable RAM DIMM.
Replace RAM DIMM.
Yes
Replace CU PCB.
No
(Must replace EEPROM)
No
Use a standard RAM DIMM.
No
Re-mount applicable RAM DIMM.
Replace RAM DIMM
Yes
Replace CU PCB.
No
(Must replace EEPROM)
No
Use a standard RAM DIMM.
No
Re-mount applicable RAM DIMM.
Replace RAM DIMM.
Yes
Replace CU PCB.
No
(Must replace EEPROM)
Yes
REPLACE EEPROM.
(User must correct
environmental conditions)
No
Replace CU PCB.
(Must replace EEPROM)
Yes
Replace CU PCB.
(Must replace EEPROM)
Replace CU PCB
(Must replace EEPROM) *1
Yes
Replace Program ROM DIMM.
No
Replace with standard program
ROM DIMM oficially for the
model.
Yes
Replace Program ROM DIMM.
No
Replace with standard program
ROM DIMM oficially for the model.
Yes
Refer to the lowchart on "Failure
to appear on LCD".
No
Normally connect.
Yes
Replace fan.
No
Replace CU PCB.
(Must replace EEPROM)
Power OFF/ON
Replace CU PCB.
(Replace EEPROM)
Power OFF/ON
Replace CU PCB.(Replace
EEPROM)
Power OFF/ON
Replace CU PCB.(Replace
EEPROM)
No
Properly mount
Yes
Replace Network
No
Replace CU PCB.
(Must replace EEPROM)
No
Replace CU PCB.
(Must replace EEPROM)
No
Properly mount
Yes
Replace CU PCB.
(Must replace EEPROM)
No
Replace PU PCB
600 1200