CONVERSION
INSTRUCTIONS
810-9521-F
CAUTION: Some parts may
contain sharp edges. Wear protective
gloves if necessary.
Note: Make sure all control
knobs are in the off
position, LP tank valve is
closed and tank is
disconnected from
regulator and removed
from grill.
Step 1
Using an adjustable wrench to hold
the gas manifold connection secure,
use a 3/4" wrench to loosen the hose
connection nut. Replace existing LP
hose/regulator assembly with natural
gas 10ʼ hose assembly. Tighten the
connection carefully using two
wrenches.
Step 2
Remove cotter pin from side burner
"foot". Carefully lift side burner up and
away from valve nozzle. Set aside for
later use.
Cotter Pin
Step 3
Open hood and remove warming
rack, cooking grills and heat shields.
Set aside for later use.
13
Gas Manifold Nut
10ʼ Natural Gas Hose
Warming Rack
Cooking Grills
Heat Shields